LC-46XL2E (serv.man4). Troubleshooting Table - Sharp TV Service Manual (repair manual). Page 22

Read Sharp LC-46XL2E (serv.man4) Service Manual online

LC-42XL2E/S/RU, LC-46XL2E/S/RU, LC-46X20E/S/RU, LC-52XL2E/S/RU, LC-52X20E/S/RU
4 – 22
<During external connection> No picture on the monitor (4)
SCART2:                             
No picture from EXT3 appears on EXT2- connected monitor.
                                            
Checklist:
1) Is the Signal Type (item) in MENU-Option-Input Select equal to Signal Type of an external device? 
⋅ ⋅ ⋅ Set it to “CVBS”, “Y/C” or “RGB”.
2) The picture is sent to the monitor in a CVBS signal if the source during display is TV, CVBS or Y/C of EXT1-3.
When sent by component, etc., that signal is not sent to the monitor.
3) When the monitor picture is not sent and is not displayed on the monitor, refer to “No picture” for each terminal.
4) The video output from EXT1 is not the monitor output (output of the picture now watching).
The picture of the last selected TV channel is always sent to EXT1. (Specification)
TERMINAL UNIT:                 
Is CVBS signal input from pin (51) of IC506 to pin (19) of 
SCART2 (SC503)?
YES
Check the setting of an external input device that connects of 
SC503.
NO
Is CVBS signal input from pin (5) of the connector P501 to pin (3) 
of IC506 (VIDEO SELECTOR)?
YES
Check the IC506 and its peripheral circuits.
MINI AV UNIT:                      
NO
Is CVBS signal input from pin (6) of the input terminal J901 to pin 
(5) of the connector (P501)?
YES
Check the connector (P501/P901)
NO
Is V3_PLUG signal of the CVBS signal detection function from 
pin (7) of  the input terminal J901 normal?
YES
Check the setting of an external input device that connects of 
J901.
NO
Check between V3_PLUG_LINE J901 and pin (2) of IC506 in the 
TERMINAL UNIT. (Connector P901/P501, etc.)
LED flashing atterns for error notification
250ms
1sec
1) Power red LED
Remarks
H: On
Lamp failure
Flashes once: Fast
L: Off
H: On
Refer to "Power failure details".
Power failure
Flashes twice
L: Off
Communication failure H: On
Refer to "Communication failure details".
with main CPU
Communication line failure or main CPU(IC8101) communication failure.
ψ Check main CPU (IC8101).
Flashes 3 times
L: Off
H: On
Monitor temp. failure
Flashes 5 times
L: Off
2) Power failure details (Power LED flashes twice and OPC LED flashes)
Remarks
H: On
12V failure
Flashes once
L: Off
H: On
10V failure
Flashes 3 times
L: Off
H: On
Digital 3.3V failure
Flashes 4 times
L: Off
H: On
Panel 5V failure
Flashes 5 times
L: Off
H: On
Main failure
Flashes 7 times
L: Off
3) Communication failure details (Power LED flashes 3 times and OPC LED flashes)
Remarks
Initial communication
H: On
reception failure
Flashes once
L: Off
Start-up confirmation
H: On
reception failure
Flashes twice
L: Off
Regular communication H: On
failure
Flashes 3 times
L: Off
H: On
Restart failure
Flashes 4 times
L: Off
When restarted by a software with the standby off/on, restart completion notification is not received.
ψ Main CPU (IC8101)restart failure to monitor microprocessor (IC2002) reception failure
ψ Main CPU (IC8101) start-up failure or monitor microprocessor (IC2002) reception failure
Regular communication that is performed at 1 second intervals in the normal operation is interrupted.
ψ Main CPU (IC8101) operation failure or monitor microprocessor (IC2002) reception failure
Initial communication from the main CPU (IC8101) is not received.
ψ Communication line failure or main CPU (IC8101) start-up failure
Start-up reason confirmation from the main CP(IC8101) is not received.
Main microprocessor detection error
The details are displayed on page 1 of process adjustment for the main microprocessor (IC8101).
Error type
OPC LED operation (1 cycle)
Description
PANEL_POW
DET_PNL5V(IC2002_58pin): Abnormal (L). Panel power is not applied.
If error is detected during start-up or operation, the power is turned on again by polling.
D_POW
DET_D3V3(IC2002_59pin): Abnormal (L). D3.3V is not applied.
If error is detected during start-up or operation, the power is turned on again by polling.
PS_ON
DET_10V(IC2002_57pin): Abnormal (L). Main power UR15V is not applied.
If error is detected during start-up or operation, the power is turned on again by polling.
PS_ON
AC_DET(IC2002_16pin): Abnormal (L). Main converter 12V is not applied.
If error is detected during operation, the power is turned on again by interrupt handling (instantaneous bl
If the panel temperature is 60 C or more for 15 seconds or more in a row, error standby is activated.
(MONITOR MAX TEMP of process adjustment (28/31): Change of temperature failure AD value): Thermistor
Error type
OPC LED operation (1 cycle)
Description
Note that after five detection counts, the lamp cannot be activated except in the monitoring process. (For
V
Accumulated counts are cleared to 0 when the corresponding setting in the process A is made, when the power
If the panel temperature is 60 C or more for 15 seconds or more in a row, CAUTION appears on the OSD of AVC
Error type
Power red LED operation (1 cycle)
Description
ERR_PNL(IC2002_43pin): Abnormal L. Confirmed after 5 consecutive detections at 1 second intervals (detected
Page of 22
Display