Read Sharp LC-46LE700E (serv.man9) Service Manual online
LC-32/40/46LE700E/RU/S,LU700E/S,LX700E/RU,LC-52LE700E/RU/S
7 – 10
2.5. IC3301 (VHiBD6538G+-1Y)
2.5.1 Block Diagram
2.5.2 Pin Connections and short description
Pin No.
Pin Name
I/O
Pin Function
1
VIN
I
Power supply input terminal.
It is an input terminal to the switch and a power supply input terminal of an internal circuit.
It is an input terminal to the switch and a power supply input terminal of an internal circuit.
2
GND
—
Ground
3
EN
I
Switch enable input terminal.
The switch is turned on by inputting the high level.
The switch is turned on by inputting the high level.
4
/OC
O
Over current notification terminal.
When the over current is detected, it becomes a low level.
Open drain output.
When the over current is detected, it becomes a low level.
Open drain output.
5
VOUT
O
Switch output terminal.
Click on the first or last page to see other LC-46LE700E (serv.man9) service manuals if exist.