LC-45GD1E (serv.man29). Trouble shooting table - Sharp TV Service Manual (repair manual). Page 13

Read Sharp LC-45GD1E (serv.man29) Service Manual online

60
TU-45GD1E
LC-45GD1E
TROUBLE SHOOTING TABLE
 (Continued)
2V/div
4.0
µ
/div
2V/div
4.0
µ
/div
2V/div
4.0
µ
/div
The picture is not displayed normally.
YES
NO
YES
NO
YES
NO
YES
NO
YES
YES
NO
YES
YES
NO
YES
NO
NO
YES
NO
YES
NO
YES
NO
NO
YES
YES
NO
NO
YES
NO
YES
NO
NO
YES
NO
NO
YES
YES
NO
YES
NO
YES
NO
YES
The test pattern is normally displayed, 
but the whole screen is white for other 
displays.
The test pattern is displayed normally, 
but the whole screen is black for other 
displays.
Is VSYNC normally input to pin (2) of 
IC4401?
Check SC2201, periphery 
of SC5301, FFC and 
periphery of IC5301.
Check IC4003, IC4001 and 
periphery of IC4004.
Is pin (5) of IC2205 3.3V?
Check IC2203, IC2201 and 
periphery of SC5301.
Are H, V and DE output from TP5301 
to TP5303?
Check the periphery of 
IC5301 and that of SC5302.
Check SC2201, periphery of 
SC5301, FFC and periphery of 
IC2203.
When switching REV DISPLAY of the 
process mode's LCD PAGE1, the 
position of the defective portion does not 
change.
The pattern is displayed every other 
line in the horizontal direction. Or, 
flicker is displayed.
Normal waveform is 
output from R4726, 
R4727, R6826 and 
R6827. (*1)
Normal waveform is 
output to TP5829 and 
TP5830. (*1)
Check the FPC 
connecting the panel.
Check the harnesses 
between TCONTOP 
and DC/DC PWB.
Normal waveform is input 
to pin (12) of P1701. (*2)
Check the harnesses 
between TCONTOP 
and DC/DC PWB, 
periphery of IC4301 
and that of P4801.
TP5831 is 16 MHz.
Check the periphery of 
X5801.
TP7851, TP7852, TP7853 
and TP7854 are 8.1V,2.9V,  
5.7V and 5.3V respectively.
Check the CSPOWER 
PWB.
Check IC5802, IC5805, 
IC5806 and periphery of 
IC5807.
Is the gradation pattern displayed 
normally when setting PATTERN1 of 
PATTERN PAGE1 in the adjustment 
process menu to 02?
The upper part of the 
screen is abnormal.
Either the left or right 
part is abnormal.
Check between IC4301 
and SC4702 as well as 
between IC4302 and 
SC4701.
Check IC4503, IC4504 and 
periphery of IC4505.
The lower part of the 
screen is abnormal.
The screen is partially 
whitish or dark.
Either the left or right 
part is abnormal.
Check IC6601, IC6602 and 
periphery of IC6603.
Check between IC6401 
and SC6802 as well as 
between IC6402 and 
SC6801.
Is the gradation pattern displayed 
normally when setting PATTERN3 of 
PATTERN PAGE1 in the adjustment 
process menu to 21?
Check between IC4101 and IC4102, 
between IC4201 and IC4202 and 
their periphery.
Are all gradations displayed normally 
when changing PATTERN A of 
PATTERN PAGE1 in the adjustment 
process menu from 0 to 255?
Check between IC4001 and IC4101, 
between IC4004 and IC4201 and 
their periphery.
For the displays other than the test 
pattern, the left half of the screen is 
abnormal.
Check between IC4004 and 
SC4002, between IC5502 and 
SC5502 and FPC.
For the displays other than the test 
pattern, the right half of the screen is 
abnormal.
Check between IC4001 and 
SC4001, between IC5501 and 
SC5501 and FPC.
The displays other than the test pattern 
are abnormal every other line in the 
vertical direction.
Check the periphery of IC5402.
For the displays other than the test 
pattern, the whole screen is abnormal.
Check between IC5301 and IC5401 
and their periphery.
(*1)
(*2)
(*3)
Page of 20