Read Sharp LC-40LE820E (serv.man5) Service Manual online
LC-40/46/52LE820E, LC-40/46LU820E
7 – 15
LED flashing timing chart at the time of the error
1) Low-speed blinking
2) Lamp failure details (Low-speed blinking: Flashes once + High-speed blinking)
3) Power failure details (Low-speed blinking: Flashes twice + High-speed blinking)
Error type
Expression of Central Icon LED
Note: Pins are monitor microprocessor pins (IC2002).
Lamp failure
low-speed blinking
Flashes once
low-speed blinking
Flashes once
H: ON
L: OFF
Refer to “Lamp failure details”.
LOW/High blinking by pressing the [MENU] key on the remote
control.
LOW/High blinking by pressing the [MENU] key on the remote
control.
Power failure
low-speed blinking
Flashes twice
low-speed blinking
Flashes twice
H: ON
L: OFF
Refer to “Power failure details”.
LOW/High blinking by pressing the [MENU] key on the remote
control.
LOW/High blinking by pressing the [MENU] key on the remote
control.
Communication
failure with main CPU
low-speed blinking
Flashes 3 times
failure with main CPU
low-speed blinking
Flashes 3 times
H: ON
L: OFF
Refer to “Communication failure details”.
LOW/High blinking by pressing the [MENU] key on the remote
control.
Communication line failure or main CPU communication failure.
LOW/High blinking by pressing the [MENU] key on the remote
control.
Communication line failure or main CPU communication failure.
Others
low-speed blinking
Flashes 4 times
low-speed blinking
Flashes 4 times
H: ON
L: OFF
Refer to “Other failure details”.
LOW/High blinking by pressing the [MENU] key on the remote
control.
LOW/High blinking by pressing the [MENU] key on the remote
control.
Error type
Expression of Central Icon LED
Note: Pins are monitor microprocessor pins unless otherwise
specified (IC2002).
specified (IC2002).
Lamp failure
Flashes once
(High speed)
(High speed)
H: ON
L: OFF
ERR_PNL (40pin): Abnormal H.
Confirmed after 8 consecutive detections at 64ms intervals
(detected only when the backlight is on).
Confirmed after 8 consecutive detections at 64ms intervals
(detected only when the backlight is on).
NOTE: After 5 detection counts, the lamp cannot be activated
except in the monitoring process.
To confirm the problem, “Lamp Error detection off-mode”
is prepared.
This mode compulsorily starts the set disregarding the
count.
Please refer to [ADJUSTMENT PROCEDURE - 7. Lamp
Error detection]
To confirm the problem, “Lamp Error detection off-mode”
is prepared.
This mode compulsorily starts the set disregarding the
count.
Please refer to [ADJUSTMENT PROCEDURE - 7. Lamp
Error detection]
Error type
Expression of Central Icon LED
Note: Pins are monitor microprocessor pins unless otherwise
specified (IC2002).
specified (IC2002).
PS_ON
AC_DET failure
Flashes once
(High speed)
AC_DET failure
Flashes once
(High speed)
H: ON
L: OFF
AC_DET (72pin: Abnormal (L).
If error is detected during start-up or operation, the power is turned
on again by interrupt handling (instantaneous blackout process-
ing).
If error is detected during start-up or operation, the power is turned
on again by interrupt handling (instantaneous blackout process-
ing).
SM_POW
Main 13V failure
Flashes twice
(High speed)
Main 13V failure
Flashes twice
(High speed)
H: ON
L: OFF
DET_13V (38pin): Abnormal (L). Main 13V is not applied.
If error is detected during start-up or operation, the power is turned
on again by polling.
If error is detected during start-up or operation, the power is turned
on again by polling.
D_POW
Digital 3.3V failure
Flashes 3 times
(High speed)
Digital 3.3V failure
Flashes 3 times
(High speed)
H: ON
L: OFF
DET_D3V3 (36pin): abnormal (L). Digital 3.3V is not applied.
If error is detected during start-up or operation, the power is turned
on again by polling.
on again by polling.
PANEL_POW
Panel 12V failure
Flashes 5 times
(High speed)
Panel 12V failure
Flashes 5 times
(High speed)
H: ON
L: OFF
DET_PNL12V (35pin): abnormal (L).
DET_PNL12V is not applied.
DET_PNL12V is not applied.
Detection starts after receiving command from Panel Power ON.
The power is turned off by polling.
The power is turned off by polling.
100ms
400ms
1.6sec
Click on the first or last page to see other LC-40LE820E (serv.man5) service manuals if exist.