LC-37XD1E (serv.man3). Adjustment Procedure - Sharp TV Service Manual (repair manual). Page 8

Read Sharp LC-37XD1E (serv.man3) Service Manual online

     LC-37XD1E/RU
3 – 8
5. Adjustment process mode menu
The character string in brackets [   ] will appear as a page title in the adjustment process menu header.
Page Line
1/13
[INFO]
1
Main Version
37/42XD1 ver 1.0C1 2006.0915
Main microprocessor version
2
Dev Version
ver1.10
DTV version.
3
Dev Loader Version
2.3
DTV Loader Version
4
Center Acutime
xxxxH xxM
Main operating hours
5
Backlight Acutime
xxxxH xxM
Backlight operating hours
6
Temp Sensor
080
Temp Sensor setting
7
Normal Standby Cause
1 RC_STANDBY
8
Error Standby Cause [1]
1c POWER ERROR 0000H 00M
Error standby cause Total operating time before error
[2]
1c POWER ERROR 0000H 00M
[3]
1c POWER ERROR 0000H 00M
[4]
0
0000H 00M
[5]
0
0000H 00M
2/13
[INIT]
1
FACTORY INIT
EURO/UK/ITALY/FRANCE/RUSSIA
Initialization to factory settings execution
2
INCH SETTING
37/42
Inch Setting
3
PUBLIC MODE
off/on
HOTEL MODE
㵘flag setting
4
Center Acutime Reset
off/on
Main operating hours Reset
5
Backlight Acutime Reset
off/on
Backlight operating hours Reset
6
Picture Read Pos X
670
x-axis setting of picture data
7
Picture Read Pos Y
419
y-axis setting of picture data
8
Picture Read Signal Type
PAL/COMP/HDMI/RGB
Signal Type Setting
9
Picture Read
0 - 1023
Start/stop of picture data
3/13
[PAL+TUNERMAIN]
1
RF-AGC BG ADJ
ENTER
RF-AGC BG adjustment execution
2
RF-AGC L ADJ
ENTER
RF-AGC L adjustment execution
3
PAL+TUNER ADJ
ENTER
PAL TUNER auto adjustment execution
4
PAL
㵘ADJ
ENTER
PAL auto adjustment execution
5
TUNER ADJ
ENTER
TUNER auto adjustment execution
6
PAL
㵘DAC
29
PAL DAC adjustment
7
TUNER A DAC
29
Tuner DAC adjustment
8
Tuner AGC BG
5
Tuner AGC BG adjustment
9
Tuner AGC L
8
Tuner AGC L adjustment
10
Tuner AGC int. off
6
Tuner AGC gain adjustment
4/13
[COMP ]
1
COMP ALL ADJ
ENTER
COMP15K auto adjustment execution
2
COMP CONTRAST
32
COMP contrast adjustment execution
3
COMP Cb GAIN
32
COMP Cb gain adjustment execution
4
COMP Cr GAIN
32
COMP Cr gain adjustment execution
5
COMP BRIGHT
0
COMP bright adjustment execution
5/13
[SCART RGB]
1
SCART RGB CONTRAST
40
SCART RGB contrast adjustment execution
2
SCART RGB Cb GAIN
40
SCART RGB Cb gain adjustment execution
3
SCART RGB Cr GAIN
40
SCART RGB Cr gain adjustment execution
4
SCART RGB BRIGHT
0
SCART RGB bright adjustment execution
6/13
[TUNER]
1
TUNER TEST
7/13
[M GAMMA INFO]
1
M GAMMA POS 1
4
W/B adjustment, gradation 1 input setting
2
M GAMMA POS 2
9
W/B adjustment, gradation 2 input setting
3
M GAMMA POS 3
14
W/B adjustment, gradation 3 input setting
4
M GAMMA POS 4
20
W/B adjustment, gradation 4 input setting
5
M GAMMA POS 5
25
W/B adjustment, gradation 5 input setting
6
M GAMMA POS 6
29
W/B adjustment, gradation 6 input setting
7
M GAMMA WRITE
off/on
EEP writing of adjustment values
8
M GAMMA RESET
off/on
Initialization of adjustment values
Item
Remarks (adjustment detail,etc.)
Description
Page of 16
Display

Click on the first or last page to see other LC-37XD1E (serv.man3) service manuals if exist.