LC-37GD8EK (serv.man9). Software Updating - Sharp TV Service Manual (repair manual). Page 3

Read Sharp LC-37GD8EK (serv.man9) Service Manual online

25
 LC-26GA5E
 LC-32GA5E
LC-32GD8E/RU  
LC-32BT8E/RU
LC-37GD8E/RU
LC-37BT8E/RU
LC-32/37GD8E/RU  
LC-32/37BT8E/RU
27
 LC-26GA5E
 LC-32GA5E
  LC-26P55E
  LC-32P55E
  LC-37P55E
2. Send the command “DWMD” to enter TV set in Download Mode. The TV set answer sending same symbol con-
tinuosly. If this symbol character doesn’t appear, please don’t worry and pass to next step.
3. Close this connection and open “P55_115200bps” 
connection clicking over the “P55_115200bps” 
that  
you can find 
in “START\All programs\Accessories\ Communications\HyperTerminal\HyperTerminal” folder.
4. Using “Transfer\Send fi le…” menu, select desired fi le (.bin format) and the transmission protocol (Xmodem) as 
show below.
5. After press “Send” button the updating process starts as follows:
 
VERY IMPORTANT NOTE:
During the updating time, please don’t use the PC for other purpouses, in order to abolish communication 
problems between TV set and PC. If TV set was not updated properly, the TV won’t have the software to startup 
again, and you must follow the “I2C method” to update another time the TV set.
6.
 When fl ash update process fi nishes, the ” Flash programming complete “ label appear in the screen , the device 
automatically go to switch off, and in a few seconds go to switch on again.
VCTp Software Updating, HyperTerminal (continued)
(*)
(*)
Page of 18
Display