LC-37GA9EK (serv.man6). Service Adjustments - Sharp TV Service Manual (repair manual). Page 3

Read Sharp LC-37GA9EK (serv.man6) Service Manual online

17
 LC-26GA5E
 LC-32GA5E
  LC-32GA9E/LC-32BV9E
  LC-37GA9E/LC-37BV9E
4 Special Features
- ERROR STAND-BY CAUSE (Page 1/11) 
  When the unit enters standby due to operational error, total time before the error and the cause of error is recorded
  on EEPROM, if possible. The values can be used to locate the fault for repair.
- EEP CLEAR (Page 10/11)
  Restore NVM data to default values.  
- EEP CLEAR B (Page 10/11)
  Restore NVM data to default values except adjustment data.
5 Video Signal Adjustment Procedure
The adjustment process mode menu is listed in Section 3.
5.1. Signal check
Signal generator level adjustment check (Adjustment to the specified level).
- Composite signal PAL 
:  0.7Vp-p ± 0.02Vp-p (Pedestal to white level)
- 15K Component signal 
:  Y level 
 
0.7Vp-p ± 0.02Vp-p (Pedestal to white level)
  (50Hz) (576i/50Hz)  
   PB, PR level   
0.7Vp-p ± 0.02Vp-p
Page  Line  Item 
Description 
Remarks (Adjustment detail, etc.) 
 
[ETC] 
10/11
1
2
3
4
5
6
7
8
9
EEP CLEAR 
EEP CLEAR B 
STAND BY CAUSE RESET 
AUTO INSTALLATION SW 
OPTION 
COUNTRY 
L ERR RESET 
L ERR STOP 
I2C-OFF 
OFF/ON 
OFF/ON 
OFF/ON 
0/1
0
AUTO
0
0/1
ENTER
Restore NVM data to default values 
Restore NVM data to default values except 
adjustment data 
Clearing of standby cause error list 
0: unfinished    1:finish (The setting takes effect 
the next time the power is turned on.) 
AUTO: defects the actual region. 
Lamp error counter 
Stops Lamp Error feature (Not operative) 
BUS STOP 
 
LCD 
11/11
1
2
3
4
5
6
7
OSC FREQ 50 
OSC FREQ 60 
PWM FREQ 50 
PWM FREQ 60 
PWM FREQ 
PWM DUTY 
PWM CTRL 
144
144
1
1
424
227
0
5.2. Entering the adjustment process mode
Enter the  adjustment process mode according to Section
 1.
5.3. RF AGC Adjustment
LC-26P50E
LC-32P50E
LC-37P50E
29
6. Special features
`
ERROR STANDBY CAUSE (Page 1/12)
When the unit enters standby due to operational error, total time before the error and the cause of error is
recorded on EEPROM, if possible.The values can be used to locate the fault for repair.
`
EEP SAVE (Page 12/12)
Storage of EEP adjustment value.
`
EEP RESTORE (Page 12/12)
Retrieval of EEP adjustment value from storage area.
7. Video signal adjustment procedure
*  The adjustment process mode menu is listed in Section 5.
(1) Signal check
Signal generator level adjustment check (Adjustment to the specified level)
» Composite signal
: 0.714Vp-p ± 0.02Vp-p (Pedestal to white level)
» Composite signal PAL
: 0.7Vp-p ±0.02Vp-p (Pedestal to white level)
» RGB signal
: 0.7Vp-p± 0.02Vp-p
» 15K component signal : Y level
0.7Vp-p±0.02Vp-p (Pedestal to white level)
(50 Hz)
PB, PR level
0.7Vp-p ±0.02Vp-p
» 33K component signal : Y level
0.7Vp-p  ± 0.02Vp-p (Pedestal to white level)
PB, PR level
0.7Vp-p ±0.02Vp-p
(2) Entering the adjustment process mode
Enter the adjustment process mode according to Section 3.
(3) RF AGC adjustment
Adjustment point Adjustment conditions
Adjustment procedure
1
Setting
[Signal]
PAL
Field Color Bar
RF signal UV
[Terminal]
TUNER
2
Auto adjustment Adjustment process page 3
performance
»
Feed the PAL  color bar signal (E-12ch) to TUNER.
Signal level: 52
±
1 dB µV (75� LOAD)
Bring the cursor on [ËRF AGC ADJ] and press [OK].
[ËRF AGC ADJ OK] appears when finished.
[E-12CH]
�100% white
Page of 7
Display

Click on the first or last page to see other LC-37GA9EK (serv.man6) service manuals if exist.