Read Sharp LC-32XL8E (serv.man4) Service Manual online
LC-32XL8E/S/RU, LC-37XL8E/S/RU
4 – 22
2) Power failure details(Power LED flashes twice and OPC LED flashes)
Error type
OPC LED operation (1 cycle)
Description
PS_ON
H: On
AC_DET(IC2002_16pin): Abnormal (L). Main converter 12V is not
applied.
applied.
12V failure
If error is detected during operation, the power is turned on again
by interrupt handling.
by interrupt handling.
Flashes once
L: Off
PS_ON
H: On
DET_10V(IC2002_57pin): Abnormal (L). Main power UR13V is
not applied.
not applied.
10V failure
If error is detected during start-up or operation, the power is
turned on again by polling.
turned on again by polling.
Flashes 3 times
L: Off
D_POW
H: On
DET_D3V3(IC2002_59pin): Abnormal (L). D3.3V is not applied.
Digital 3.3V failure
If error is detected during start-up or operation, the power is
turned on again by polling.
turned on again by polling.
Flashes 4 times
L: Off
PANEL_POW
H: On
DET_PNL12V(IC2002_58pin): Abnormal (L). Panel power is not
applied.
applied.
Panel 12V failure
If error is detected during start-up or operation, the power is
turned on again by polling.
turned on again by polling.
Flashes 5 times
L: Off
Main failure
H: On
Main microprocessor detection error
The details are displayed on page 1 of process adjustment for the
main microprocessor (IC8101).
The details are displayed on page 1 of process adjustment for the
main microprocessor (IC8101).
Flashes 7 times
L: Off
3) Communication failure details(Power LED flashes 3 times and OPC LED flashes)
Error type
OPC LED operation (1 cycle)
Description
Initial communica-
tion reception failure
tion reception failure
H: On
Initial communication from the main CPU (IC8101) is not received.
→Communication line failure or main CPU (IC8101) start-up fail-
ure
→Communication line failure or main CPU (IC8101) start-up fail-
ure
Flashes once
L: Off
Start-up confirma-
tion reception failure
tion reception failure
H: On
Start-up reason confirmation from the main CP(IC8101) is not
received.
→Main CPU (IC8101) start-up failure or monitor microprocessor
(IC2002) reception failure
received.
→Main CPU (IC8101) start-up failure or monitor microprocessor
(IC2002) reception failure
Flashes twice
L: Off
Regular communi-
cation failure
cation failure
H: On
Regular communication that is performed at 1 second intervals in
the normal operation is interrupted.
→Main CPU (IC8101) operation failure or monitor microprocessor
(IC2002) reception failure
the normal operation is interrupted.
→Main CPU (IC8101) operation failure or monitor microprocessor
(IC2002) reception failure
Flashes 3 times
L: Off
Restart failure
H: On
When restarted by a software with the standby off/on, restart com-
pletion notification is not received.
→Main CPU (IC8101)restart failure to monitor microprocessor
(IC2002) reception failure
pletion notification is not received.
→Main CPU (IC8101)restart failure to monitor microprocessor
(IC2002) reception failure
Flashes 4 times
L: Off
Click on the first or last page to see other LC-32XL8E (serv.man4) service manuals if exist.