61
LC-32SH130E
LC-32SH130K
LC-32SH340E
20. MP1583 (U174)
20.1.
General Description
The MP1583 is a step-down regulator with a built-in internal Power MOSFET. It achieves 3A of continuous 
output current over a wide input supply range with excellent load and line regulation. Current mode 
operation provides fast transient response and eases loop stabilization. Fault condition protection 
includes cycle-by-cycle current limiting and thermal shutdown. An adjustable soft-start reduces the 
stress on the input source at start-up. The MP1583 requires a minimum number of external components, 
providing a compact solution.
20.2.
Features 
3A Output Current
Programmable Soft-Start
100mΩ Internal Power MOSFET Switch
Stable with Low ESR Output Ceramic Capacitors
Up to 95% Efficiency
20μA Shutdown Mode
Fixed 385KHz Frequency
Thermal Shutdown
Cycle-by-Cycle Over Current Protection
Wide 4.75V to 23V Operating Input Range
Output Adjustable from 1.22V to 21V
Under-Voltage Lockout
20.3.
Pinning
Pin 
No.
Pin 
Name
Description
1
BOOT
High-Side Gate Drive Bootstrap Input. BS supplies the drive for the 
high-side N-Channel MOSFET switch. 
2
IN
Power Input. Drive IN with a 4.75V to 23V power source. 
3
SW
Power Switching Out is the switching node that supplies power to the 
output
4
GND
Ground.
5
FB
Feedback Input. FB senses the output voltage and regulates it. Drive 
FB with a resistive voltage divider from the output voltage. FB 
threshold is 1.222V. 
6
COMP
Compensation Node is used to compensate the regulation control 
loop. 
7
EN
Enable/UVLO. A voltage greater than 2.71V enables operation. For 
complete low current shutdown the EN pin voltage needs to be at less 
than 900mV. When the voltage on EN exceeds 1.2V, the internal 
regulator will be enabled and the soft-start capacitor will begin to 
charge. The MP1583 will start  switching after the EN pin voltage 
reaches 2.71V.
8
SS
Soft-Start Control Input. SS controls the soft-start period. 