01/17
[SHARP FACTORY MENU
7
ETC
EEP, Autoinstallation, Op-
tion, Country, L Error...
Press “OK” to enter to ETC Submenu
09/17
EEP Clear
Press “
Ź
” to
 
Clear NVM data
EEP Clear B
Press “
Ź
” to Clear NVM data (except adjustments area).
Standby cause reset
“OK“ will be displayed 
Press “
Ź
” to Reset of STANDBY CAUSE.
Autoinstallation SW
Off
On: Pending to execute on next power on. Off: Not required.
Pattern
0
Selection of internal pattern from 0 up to 6…
L Error Reset
0
Press “
Ź
” to LAMP ERR RESET. Initialization of L_ERR.
L Error Check 
On
L_ERR detection. ON: activated. OFF: deactivated.
I2C OFF
Off
I2C BUS status. On: free BUS. Off: Normal. 
Sharp protocol
On
Remote Control Protocol. On: SHARP Off: MSTAR.
8
PUBLIC MODE (1/2)
PUBLIC MODE Submenu
Press  “OK”  to  enter  to  PUBLIC  MODE  Sub-
menu
10/17
Power On  xed
Variable
Press “
Ż
”  or  “
Ź
” to change Variable/Fixed.
Maximum volume
60
Press “
Ż
”  or  “
Ź
” to change 0/60.
Volume  xed
Variable
Press “
Ż
”  or  “
Ź
” to change Variable/Fixed.
Volume  xed Level
20
 Press “
Ż
”  or  “
Ź
” to change 0/60.
RC button
Respond
Press “
Ż
”  or  “
Ź
” to change Respond/No respond.
Panel button
Respond
Press “
Ż
”  or “
Ź
” to change Respond/No respond.
Menu button
Respond
Press “
Ż
”  or  “
Ź
” to change Respond/No respond.
On screen display
On
Press “
Ż
”  or  “
Ź
” to change On/Off.
Input mode start
Normal
Press “
Ż
”  or  “
Ź
” to change Normal/TV/SCART/…
Input mode  xed
Variable
Press “
Ż
”  or  “
Ź
” to change Variable/Fixed.
Input TV mode program 
number
Normal
Press “
Ż
”  or  “
Ź
” to change Normal 
ĺ 1 ĺ 2 ...999 
ĺ Normal).
RC path through
Off
Press “
Ż
”  or  “
Ź
” to change On/Off (required external 
module)
PUBLIC MODE (2/2)
PUBLIC MODE Submenu
11/17 Hotel 
mode
Off
Press “
Ż
”  or  “
Ź
” to change On/Off.
Reset
“OK“ will be displayed
Press “
Ż
”  or “
Ź
” to return to factory settings.
Execute
“OK“ will be displayed
Press “
Ż
”  or “
Ź
” to confirm.
9
SMART 
LOADER
SMART LOADER Sub-
menu
Press “OK” to enter to SMART LOADER Sub-
menu
12/17
Save settings to USB
(“OK“  or  “NO  USB  drive 
available, please check 
and/or insert USB dri...” 
will be displayed).
Press “
Ż
”  or “
Ź
” to Save.
(“OK” or “NO USB drive available, please check 
and/or insert USB dri…” will be displayed).
Load settings from USB
(“OK,  reboot  TV  set“  or 
“NO USB drive available, 
please check and/or in-
sert USB dri...” will be dis-
played).
Press “
Ż
”  or “
Ź
” to Load.
10
ADC ADJUST
ADC ADJUST Submenu
Press “OK” to enter to ADC ADJUST Submenu
13/17
MODE
YPbPr(SD)
Press “
Ż
”  or  “
Ź
” to change RGB/YPbPr(SD)/ YPbPr(HD).
ADJUST
External signal
Press “
Ż
”  or  “
Ź
” to change Internal signal/External signal. 
External: factory. Internal: service
R-GAIN
80
Press “
Ż
”  or  “
Ź
” for manual adjustment.
G-GAIN
70
Press “
Ż
”  or  “
Ź
” for manual adjustment.