1
LC-32LD164
LC-32LD165
LC-32LD166
SERVICE   MANUAL 
  LED LCD 
COLOUR TELEVISION
160mm
125mm
100mm
80mm
63mm
50mm
40mm
31.5mm
25mm
20mm
A-data-1
sharp.
Corporate Trademark
DVB-T /T2/ DVB-C  (HDTV), PAL
 
B/G, I 
/ SECAM
 B/G, D/K, L/L’ 
SYSTEM COLOUR TELEVISION
In the interests of user safety (required by safety 
regulations in some countries) the set should be re-
stored to its original condition and only parts identical 
to those specified should be used.
CONTENTS
TABLE OF CONTENTS .......................................................................................................................      2
ELECTRICAL SPECIFICATIONS .......................................................................................................      3
IMPORTANT SERVICE SAFETY PRECAUTIONS  ................................................................................       4 
OPERATION MANUAL  ...........................................................................................................................       7
DIMENSIONS  ....................................................................................................................................    13 
INTRODUCTION ...............................................................................................................................   14
REMOVING MAJORS PARTS ......................................................................................................   16 
CIRCUIT DESCRIPTIONS....................................................................................................................    20
SERVICE ADJUSTMENTS..............................................................................................................  35
SOFTWARE UPDATE ..............................................................................................................................    40
TROUBLESHOOTING  ............................................................................................................................    46 
SCHEMATIC DIAGRAMS ........................................................................................................................    53
PRINTED WIRING BOARD.............................................................................................................  76
OVERALL WIRING DIAGRAM .......................................................................................................  81
CABINET AND MAIN COMPONENTS ...............................................................................................    82
REPLACEMENT PART LISTING..........................................................................................................    87
PACKING ASSEMBLY ..................................................................................................................... 103
                       Issued:12
th 
 May 2014
SE00LC32LD164
MODEL
LC-32LD164E
LC-32LD165E
LC-32LD166K
LC-32LD165RU
Supplied accessories
DE Mitgeliefertes Zubehör
SK Dodané príslušenstvo
FR Accessoires fournis
DA Medfølgende tilbehør
IT Accessori forniti
NO Tilbehør som følger med
NL Meegeleverde accessoires
ET Komplekti kuuluvad tarvikud
ES Accesorios suministrados
LV Komplektā ietvertie piederumi
EL Παρεχόμενα εξαρτήματα
LT Pateikiami priedai
PT Acessórios fornecidos
SL Dobavljeni dodatki
SV Medföljande tillbehör
BU Принадлежности в комплекта
SU Toimitukseen kuuluvat lisävarusteet
SE Isporučena dodatna oprema
RU Аксессуары
RO Accesorii furnizate
PL Dostarczone akcesoria
SR Приложена додатна опрема
TR Verilen aksesuarlar
UK Аксесуари в комплекті
HU Mellékelt tartozékok
KK Ұсынылатын қосымша керек-жарақтар
CS Dodávané příslušenství
LD264 / LD265
LD164 / LD165
LD266 / LD166
Operation Manual
x 4
32”
46”
50”
x 4
x 4
42”
Quick Start Guide
SHARP  CORPORATION
2
LC-32LD164
LC-32LD165
LC-32LD166
TABLE OF CONTENTS 
1.  SPECIFICATIONS…....................................................................................................................  3 
2.  IMPORTANT SERVICE SAFETY PRECAUTIONS.....................................................................   4 
3.  OPERATION MANUAL...............................................................................................................   7 
4.  DIMENSIONS..............................................................................................................................  13 
5.  INTRODUCTION ........................................................................................................................  14 
5.1. General Block Diagram  ..............................................................................................  14 
5.2. MB60 Placement of Blocks.......................................................................................... 15 
6.  ASSY PANEL REMOVAL………………………………………………………………………………  16 
7.  MAJORS INFORMATIONS…………………………………………………………………………….  20 
7.1 U401 (HT5561JUDT / HT5561PUDT)……………………………………………………… 20 
7.2 U101 (CXD2837ER)…………………………………………………………………………. 23 
7.3 U405 (TC58NVG0S3HTAI0)………………………………………………………………...  24 
7.4 U414 (74HC4052PW)………………………………………………………………………..  25 
7.5 U601 (TSD5721)……………………………………………………………………………..  25 
7.6 IC9101 (SSC9522S-TL)……………………………………………………………………..  26 
8.  DETAILED ICS INFORMATION……………………………………………………………………….  27 
8.1 U401 (HT5561JUDT / HT5561PUDT)……………………………………………………… 27 
8.2 U101 (CSD2837ER)………………………………………………………………………….. 30 
8.3 U405 (TC58NVG053HTAI0)…………………………………………………………………. 31 
8.4 U414 (74HC4052PW)………………………………………………………………………… 32 
8.5 U601 (TAS5721)………………………………………………………………………………. 33 
8.6 IC9101 (SSC9522S-TL)……………………………………………………………………… 34 
9.  ADJUSTMENT PROCEDURE…………………………………………………………………………. 35 
9.1 OSD MENU……………………………………………………………………………………. 35 
9.2 ADC ADJUSTMENT AND WHITE BALANCE ADJUSTAMENT………………………… 39 
10.  SOFWARE UPDATE.................................................................................................................. 40 
10.1 Introduction..................................................................................................................  41 
10.2 Connect to ISP board to upgrade board loader………………………………………….  41 
10.3 Connect to USB port to upgrade the software…………………………………………… 44 
11.  TROUBLESHOOTING TABLE……………………………………………………….…….….….….  46 
12.  POWER TREE...........................................................................................................................  52 
13.  SCHEMATIC DIAGRAMS ………………………........................................................................  53 
14.  PRINTED WIRING BOARD………………………………………………………………………….. 76 
15.  OVERALL WIRING DIAGRAM……………………………….......................................................  81 
16.  CABINET AND MAIN COMPONENTS......................................................................................  82 
17.  REPLACEMENT PART LISTING…………………………………………………………………….  87 
18.  PACKING ASSEMBLY……………………………………………………………………………….. 103   
3
LC-32LD164
LC-32LD165
LC-32LD166
ELECTRICAL SPECIFICATIONS
LC-50LD264–LC-50LD265–LC-50LD265RU–LC-50LD266
 
CHAPTER 1.
 
OPERATION MANUAL
 
       SPECIFICATIONS 
Item 
LC-32LD164E 
LC-32LD165E 
   LC-32LD165RU
 
LC-32LD166K 
 l
a
n
o
g
a
i
d
 
” / 80cm
32
 
e
z
i
s
 
n
e
e
r
c
s
 
D
C
L
)
s
t
o
8
6
7
 
x
 
6
6
3
1
s
t
o
d
 
4
6
2
,
47
1
,
3
 
s
t
o
d
 f
o
 r
e
b
m
u
N
 
 
0
6
 
L
A
P
/
3
4
.
4
 
C
S
T
N
/
8
5
.
3
 
C
S
T
N
/
M
A
C
E
S
/
L
A
P
 
m
e
t
s
y
s
 r
u
o
l
o
c
 
o
e
d
i
V
TV Function 
TV-
Standard 
 
 )
K
/
D
,I
,
G
/
B
(
R
I
C
C
 
e
u
g
o
l
a
n
A
Digital 
DVB-T(2K/8K OFDM),DVB-C,  
DVB-T2 (only LD165) 
DVB-T(2K/8K OFDM),DVB-T2 
Receiving 
Channel 
VHF/UHF 
ATV: IRA-E69, DVB-T: E5-E69 
CATV
 
S-band, S1-S41ch 
TV-Tuning System
 
Auto Preset 1599ch, Auto Label, Auto Sort 
Stereo/bilingual 
NICAM/A2 
 
W
5
 r
e
if
il
p
m
a
 
o
i
d
u
A
× 2 
 )
H
(
2
3
1
 )
m
m
r
e
k
a
e
p
S
× 34(W) × 30(D) 
Rear 
5
7
 
F
H
V
/
F
H
U
 
A
N
N
E
T
N
A
Ω  
 t
u
p
t
u
o
 
V
T
 ,
t
u
p
n
B
G
R
 ,
t
u
p
n
C
/
Y
 ,
t
u
p
n
V
A
(
T
R
A
C
S
 
T
R
A
C
S
 r
o
t
c
e
n
n
o
c
 
k
r
o
w
t
e
N
 
A
/
N
 
T
E
N
R
E
H
T
E
 
 
T
N
E
N
O
P
M
O
C
Digital Audio out 
Optical Digital audio output 
× 1 (PCM) 
 
C
R
A
 ,
t
u
p
n
o
i
d
u
a
 
d
n
a
 
o
e
d
i
v
 l
a
ti
g
i
D
 
1
 I
M
D
H
 t
u
p
n
o
i
d
u
a
 
d
n
a
 
o
e
d
i
v
 l
a
ti
g
i
D
 
2
 I
M
D
H
Side 
C.I.(Common Interface) 
EN50221, R206001, CI Plus specification 
 
y
a
l
p
 
a
i
d
e
m
-i
tl
u
m
 ,
e
t
a
d
p
u
 
e
r
a
w
tf
o
S
 
B
S
U
 )
t
u
p
t
u
o
 
o
i
d
u
A
k
c
a
m
m
5
.
3
 
Ø
 
E
N
O
H
P
D
A
E
H
OSD language 
English, German, French, Italian, Dutch, Spanish, Greek, Portuguese, Swedish, 
Finnish, Russian, Polish, Turkish, Hungarian, Czech, Slovak, Danish, Norwegian, 
Estonian, Latvian, Lithuanian, Slovenian, Bulgarian, Croatian, Romanian, Serbian, 
Ukrainian 
 
z
H
0
5
 ,
V
0
4
2
-
0
2
2
 
C
A
 t
n
e
m
e
ri
u
q
e
R
 r
e
w
o
P
 )
7
8
0
2
6
C
E
d
o
h
t
e
M
)
W
 
3
.
0
 
<
 
y
b
d
n
a
t
S
W
 
3
5
 
n
o
it
p
m
u
s
n
o
C
 r
e
w
o
P
Weight 
Without stand 
5.84 kg 
With stand 
6.2 kg 
Operating temperature 
 0
°C to + 40°C 
 
•  As a part of policy of continuous improvement, SHARP reserves the right to make design and specification changes for product improvement 
              without prior notice. The performance specification figures indicated are nominal values of production units. There may be some deviations from 
    these values in individual units. 
 
CVBS/Y/Pb(Cb)/Pr(Cr),RCA pin (L/R)
-----
-----
DVB-T: E5-E69
-----
4
LC-32LD164
LC-32LD165
LC-32LD166
LC-20B5E
TO EXPOSED
METAL PARTS
CONNECT TO
KNOWN EARTH
GROUND
DVM
AC SCALE
1.5k ohm
10W
0.15 µF
TEST PROBE
SAFETY NOTICE
Many electrical and mechanical parts in LCD television have special safety-related characteristics.
These characteristics are often not evident from visual inspection, nor can protection afforded by them be necessarily 
increased by using replacement components rated for higher voltage, wattage, etc.
Replacement parts which have these special safety characteristics are identified in this manual; electrical components 
having such features are identified by    “    “.
For continued protection, replacement parts must be identical to those used in the original circuit.
The use of a substitute replacement parts which do not have the same safety characteristics as the factory recommended 
replacement parts shown in this service manual, may create shock, fire or other hazards.
IMPORTANT SERVICE SAFETY PRECAUTION
Service work should be performed only by qualified service technicians who are thoroughly familiar with all 
safety checks and the servicing guidelines which follow:
WARNING
1. For continued safety, no modification of any circuit should be attempted.
2. Disconnect AC power before servicing.
BEFORE RETURNING THE RECEIVER (Fire & Shock Hazard)
Before returning the receiver to the user, perform the following safety checks:
1. Inspect all lead dress to make certain that leads are not pinched, and check that hardware is not lodged between the 
chassis and other metal parts in the receiver.
2. Inspect all protective devices such as non-metallic control knobs, insulation materials, cabinet backs, adjustment and 
compartment covers or shields, isolation resistor-capacitor networks, mechanical insulators, etc.
3. To be sure that no shock hazard exists, check for leakage current in the following manner. 
• Plug the AC cord directly into a 220~240 volt AC outlet. (Do not use an isolation transformer for this test).
•Using two clip leads, connect a 1.5k ohm, 10 watt resistor paralleled by a 0.15µF capacitor in series with all exposed metal 
cabinet parts and a known earth ground, such as electrical conduit or electrical ground connected to an earth ground.
•A true RMS reading multimeter should be used for this test, especially where the equipment uses a switch mode 
power supply which may result in very non-sinusoidal leakage current.
•Connect the resistor connection to all exposed metal parts having a return to the chassis (antenna, metal cabinet, 
screw heads, knobs and control shafts, escutcheon, etc.) and measure the AC voltage drop across the resistor.
All checks must be repeated with the AC cord plug connection reversed. (If necessary, a nonpolarized adaptor plug must 
be used only for the purpose of completing these checks.)
Any reading of 1.05V peak (this corresponds to 0.7 mA. peak AC.) or more is excessive and indicates a potential shock 
hazard which must be corrected before returning the monitor to the owner.
!
  
CAUTION: FOR CONTINUED PROTECTION AGAINST A RISK OF
  FIRE REPLACE ONLY WITH SAME TYPE  
 
F9901, F9902 (T  5A/250V)
Page of 106
Display

Download Sharp LC-32LD166K (serv.man3) Service Manual (Repair Manual)

Here you can read online and download Sharp LC-32LD166K (serv.man3) Service Manual in PDF. LC-32LD166K (serv.man3) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp LC-32LD166K (serv.man3) LCD. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.