LC-32GD7E (serv.man2) - Sharp TV Service Manual (repair manual). Page 9

Read Sharp LC-32GD7E (serv.man2) Service Manual online

9
LC-32GA7L/GS7L
ADJUSTMENT PROCEDURE
The adjustment values are set to the optimum conditions at the factory before shipping.  If a value should
become improper or an adjustment is required due to part replacement, make an adjustment according to the
following procedure.
Caution: Use due care in handling the information described here lest your users should know
how to enter the adjustment process mode.  If the settings are tampered in this mode,
unrecoverable system damage may result.
1. Display adjustment procedure
1. Adjustment procedure
    Enter the display process mode and then adjust COM BIAS.
Key
Function 1 (when on the left side of a page)
Function 2 (when changing a numeric value)
Cursor UP
Cursor DOWN
Cursor RIGHT
Cursor LEFT
OK
INPUT mark of the
   R/C (caution required)
CH (
ù)
CH (
Ù)
VOL (+)
VOL (–)
Moving up by one item or moving to the previous
page (when at the top)
Moving down by one item or moving to the next
page (when at the bottom)
Moving to the right by one item or moving to
another page (in the case of the initial page)
Moving to the left by one item or moving to
another page (in the case of the initial page)
Test pattern off
Moving to the next page
Moving up by one item or moving to the previous
page (when at the top)
Moving down by one item or moving to the next
page (when at the bottom)
Moving to the right by one item or moving to
another page (in the case of the initial page)
Moving to the left by one item or moving to
another page (in the case of the initial page)
Incrementing the adjustment value by one or
executing the item (in the case of W or R item)
Decrementing the adjustment value by one or
executing the item (in the case of W or R item)
Moving to the right by one item
Moving to the left by one item
Executing the item (in the case of W or R item)
Moving to the next page
Incrementing the adjustment value by one or
executing the item (in the case of W or R item)
Decrementing the adjustment value by one or
executing the item (in the case of W or R item)
Moving to the right by one item
Moving to the left by one item
2. Adjustment process mode key operation table
3. COM BIAS adjustment
Shift to the [COM BIAS] item with the cursor UP/DOWN key and select a numeric value with the cursor
RIGHT/LEFT key.
Changing the numeric value with the cursor UP/DOWN key will make appear the test pattern.  Make an
adjustment so that the flicker near the center of the screen is minimized.