Read Sharp LC-32GA9EK (serv.man42) Technical Bulletin online
LCD 2006 08 04
Date of Issue: 1
st
August 2006
Classification:
White
LCD TELEVISION TECHNICAL BULLETIN
Page 1 of 1
Sharp Electronics (UK) Limited
Reference - SP061702X
Revision - 1
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
Red – Carry out on all units
MODELS
LC32GA9EK
LC37GA9EK
SYMPTOM No picture after the set has warmed up. Backlight and audio on.
CAUSE
IC3002.
ACTION
Update the VCT software to the latest version.
1. Replace IC3002 with the part number given below.
2. Update the VCT software to the current version.
3. Ensure that the 'Inch Setting' is set to the correct screen size.
4. Set the country in the adjustment mode:
2. Update the VCT software to the current version.
3. Ensure that the 'Inch Setting' is set to the correct screen size.
4. Set the country in the adjustment mode:
i.
Enter the adjustment process mode.
ii. Bring the cursor to 'FACTORY INIT'.
iii. Use the Volume keys to select the couture.
iv. Press Enter. 'EXECUTING' appears and the initialisation starts.
v. DO NOT turn off the unit during this process.
vi. After a while 'OK' is displayed.
vii. Exit the adjustment mode.
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
IC3002
IC, VCTP6993G
RH-IXB698WJN1Q
BV
Display