Read Sharp LC-32FH500 (serv.man7) Service Manual online
17
3. Remote control key operation and description of display in adjustment process mode.
1. key operation
Remote control key
Keyboard unit
Function
Cursor (▼/▲ )
P (
s
/
r
)
Moving an item (line) by one (up/down) on “Sharp Factory Menu”
or submenus.
or submenus.
OK
b
Selecting a submenu on lines 5 to 12 of “Sharp Factory Menu” or
executing a function.
executing a function.
Cursor (◄/►)
V (+/-)
Changing a selected item setting value.
MENU
MENU
Return to “Sharp Factory Menu” from a submenu.
The required input mode should be switched previously to enter the Service Mode.
CAUTION: Use due care in handling the information described here lest the users should know how to enter the
adjustment process mode. If the settings are tampered with in this mode, unrecoverable system
damage may result.
adjustment process mode. If the settings are tampered with in this mode, unrecoverable system
damage may result.
4. Description of display
Figure 1: Main Service Adjustment Menu
← Informative (Main microprocessor version).
← Informative.
← Informative (Remote Control/Keyboard…).
← Informative (None/Lamp Error).
← Press “OK” to go to INIT submenu.
← Press “OK” to go to ADJUST submenu.
← Press “OK” to go to ETC submenu.
← Press “OK” to go to PUBLIC MODE submenu.
← Press “OK” to go to SMARTLOADER submenu.
← Press “OK” to go to ADC ADJUST submenu.
← Press “OK” to go to GAMMA submenu.
← Press “OK” to go to SYSTEM INFORMATION submenu.
← Informative.
← Informative (Remote Control/Keyboard…).
← Informative (None/Lamp Error).
← Press “OK” to go to INIT submenu.
← Press “OK” to go to ADJUST submenu.
← Press “OK” to go to ETC submenu.
← Press “OK” to go to PUBLIC MODE submenu.
← Press “OK” to go to SMARTLOADER submenu.
← Press “OK” to go to ADC ADJUST submenu.
← Press “OK” to go to GAMMA submenu.
← Press “OK” to go to SYSTEM INFORMATION submenu.
←
←
←
←
←
←
←
←
←
←
←
←
←
←
←
←
←
←
←
←
←
←
←
←
SHARP FACTORY MENU
Main version
32FH510E SHARP v1.21 SEES v71t MSTAR CL233434
Bootloader version
BD_MST064E_C01A 2
Normal standby cause
Remote control
Error standby cause
None
INIT
ADJUST
ETC
PUBLIC MODE
SMARTLOADER
ADC ADJUST
GAMMA
SYSTEM INFORMATION
ADJUST
ETC
PUBLIC MODE
SMARTLOADER
ADC ADJUST
GAMMA
SYSTEM INFORMATION
No. Description
Display specifi cation
(1)
Service Information
Current Software version and others.
(2)
Item name
Submenus to be checked or adjusted (by pressing “OK” button)
(3)
Factory init and Inch setting
Are shown on INIT submenu
(2)
(3)
4
3
4
3
3
2
C
C
S
1
SS
S
1
2
1
SS
0
1
2
32
3
344
(1)
LC-32FH500
LC-32FH510
LC-32FH510
Click on the first or last page to see other LC-32FH500 (serv.man7) service manuals if exist.