LC-32D65 (serv.man4). Adjustment Procedure - Sharp TV Service Manual (repair manual). Page 2

Read Sharp LC-32D65 (serv.man4) Service Manual online

LC-32D65E/RU, LC-37D65E/RU
3 – 2
2. Entering and exiting the adjustment process mode
1. Unplug the AC power cord of running TV set to force off the power.
2. While holding down the “VOL (-)” and “INPUT” keys on the set at once, plug in the AC power cord to turn on the power.
The letter “K” appears on the screen.
3. Next, hold down the “VOL (-)” and “P ( 
)” keys on the set at once.
Multiple lines of blue characters appearing on the screen indicate that the set is now in the adjustment Process mode.
If you fail to enter the adjustment process mode (the display is the same as normal startup), retry the procedure.
4. To exit the adjustment process mode after the adjustment is done, unplug the AC power cord to force off the power. (When the power is turned off
with the remote controller, once unplug the AC power cord and plug it in again. In this case, wait 10 seconds or so before plugging.)
3. Remote controller key operation and description of display in adjustment process mode.
1. key operation
Input mode is switched automatically when relevant adjustment is started so far as the necessary input signal is available.
4. Description of display
CAUTION: Use due care in handling the information described here lest the users should know how to enter the adjustment process mode. If the 
settings are tampered with in this mode, unrecoverable system damage may result.
Remote controller key
Main unit key
Function
P (
/
)
P (
/
)
Moving an item (line) by one (UP/DOWN)
VOL (+/-)
VOL (+/-)
Changing a selected item setting (+1/-1)
Cursor (
/
)
Turning a page (PREVIOUS / NEXT)
Cursor (</>)
Changing a selected line setting (+10/-10)
INPUT
INPUT
Input source switching (toggle switching) (TV
→EXT1~8)
RETURN
Returning to a present page.
OK
Executing a function.
No.
Description
Display specification
(1)
Page of present number of total pages 2char/2char Decimal Number mark.
(2)
Input that has been selected now
TV/ EXT1/ EXT2/ EXT3/ EXT4/ HDMI1/ HDMI2/ HDMI3/ EXT8
(3)
Present colour system
NTSC/ PAL/ SECAM/ COMP15K/ COMP33K/ COMP45K/COMP28K/ COMP31K
(4)
Inducing display
EUROPE/ RUSSIA/ SWEDEN
(5)
Model name
MODEL NAME
(6)
Item name
Max. 30 char
(7)
Parameter
Max. 60 char
(1) Page/ of present number of total pages
(4) Inducing display
(3) Present colour system
(2) Input that has been selected now
(5) Model name
1/16
INPUT1
AUTO
EURO
37E_D65
MAIN Version
BOOT Version
Monitor Version
CPLD Version
FRC Version
EQ DATA CHECKSUM
LAMP ERROR
MONITOR ERR CAUSE
NORMAL STANDBY CAUSE
ERROR STANDBY CAUSE
1.00 (E 2008/07/10 D)
1.0
a6
ROM
0
11 11 11 11
0
1) 0
2) 0
3) 0
0H 0M
0H 0M
0H 0M
4) 0
5) 0
0H 0M
0H 0M
(6) Item name
(7) Parameter
Page of 16