LC-32AD5E - Sharp TV Service Manual (repair manual). Page 17

Read Sharp LC-32AD5E Service Manual online

C-2
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
The unit will now have the correct DATA for the new MEMORY IC.
ADDRESS is now selected and should "blink". Using the UP/DOWN buton on the remote, step through the ADDRESS
until required ADDRESS to be changed is reached.
Press LEFT/RIGHT button to select DATA. When DATA is selected, it will "blink".
Again, step through the DATA using UP/DOWN button until required DATA value has been selected.
Pressing LEFT/RIGHT button will take you back to ADDRESS for further selection if necessary.
Repeat steps 4 to 6 until all data has been checked.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
After the data input, set to the initializing of shipping.
Turn on the Power.
Set the VOLUME to minimum.
Press both VOL. DOWN button on the set and Channel button (1) on the remote control for more than 2 seconds.
After the finishing of the initializing of shipping, the unit will turn off automatically.
ADDRESS
DATA
INIT         0000      00
LCD ON  0000
ANALOG M  : DB060_70508A
ANALOG S   : DB050_70409B
FIG. 2
1.
2.
3.
Turn on the POWER, and set to the TV mode.
Set the VOLUME to minimum.
Press both VOL. DOWN button on the set and Channel button (6) on the remote control for more than 2 seconds.
ADDRESS and DATA should appear as FIG 2.
1.
2.
3.
4.
Version
Hardware version         A.0
Software version          CB00C75091
                OK               END
   INIT      : 5512
   VCT-P  : A60D          LCD ON : 0000
ANALOG M  : DB060_70508A
ANALOG S   : DB050_70409B
FIG. 1
Turn on the POWER, and set to the TV mode.
Set the VOLUME to minimum.
Press both VOL. DOWN button on the set and Channel button (2) on the remote control for more than 2 seconds.
After the confirmation of MICON VERSION and Digital TV MICON Firmware, turn off the power.
ADDRESS and DATA should appear as FIG 1.
CONFIRMATION OF CHECK SUM, MICON VERSION, DIGITAL TV MICON FIRMWARE AND
POWER ON TOTAL
Initial total of MEMORY IC, MICON VERSION,  Digital TV MICON Firmware and POWER ON TOTAL HOURS can be
checked on the screen. Total hours are displayed in 16 system of notation.
NOTE:
WHEN REPLACING EEPROM (MEMORY) IC
If you set a factory initialization, the total hours is reset to "0".
Please refer to "CONFIRMATION OF INITIAL DATA" when SUM DATA is not corresponding.
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be
taken to ensure correct data settings while making reference to INITIAL SETTING TABLE (Attached "INITIAL DATA").
CONFIRMATION OF INITIAL DATA
Initial setting data check sum.
POWER ON total hours.
 = (16 x 16 x 16 x thousands digit value)
 + (16 x 16 x hundreds digit value)
 + (16 x tens digit value)
 + (ones digit value)
Digital Fimware Fimware
SCALER data check sum.
NOTE: The each item value might be different according to each set.
Main Micon check Version
Sub Micon check Version
Digital 
Hardware
 Fimware
Page of 92
Display

Click on the first or last page to see other LC-32AD5E service manuals if exist.