Read Sharp LC-30AD1E (serv.man7) Service Manual online
20
LC-30AD1E
RS232C command table
Command
MSET1001
MOFR
MSET1001
MOFR
~~~~
MOFG
~~~~
MOFB
~~~~
MGAR
~~~~
MGAG
~~~~
MGAB
~~~~
MINF0000
MINF0001
MINF0002
MINF0001
MINF0002
Function
Used to start the background adjustment.
Used to adjust the value of R OFFSET.
Used to adjust the value of G OFFSET.
Used to adjust the value of B OFFSET.
Used to adjust the value of R GAMMA.
Used to adjust the value of G GAMMA.
Used to adjust the value of B GAMMA.
Used to display the R GAMMA table.
Used to display the B GAMMA table.
Used to display the G GAMMA table.
Used to start the background adjustment.
Used to adjust the value of R OFFSET.
Used to adjust the value of G OFFSET.
Used to adjust the value of B OFFSET.
Used to adjust the value of R GAMMA.
Used to adjust the value of G GAMMA.
Used to adjust the value of B GAMMA.
Used to display the R GAMMA table.
Used to display the B GAMMA table.
Used to display the G GAMMA table.
Remarks
The adjustment ends with a numeric value other than 1001.
Range: 0000 to 0512 (Initial value: 0255)
Range: 0000 to 0512 (Initial value: 0255)
Range: 0000 to 0512 (Initial value: 0255)
Range: 0000 to 0255 (Initial value: 0100)
Range: 0000 to 0255 (Initial value: 0100)
Range: 0000 to 0255 (Initial value: 0100)
The adjustment ends with a numeric value other than 1001.
Range: 0000 to 0512 (Initial value: 0255)
Range: 0000 to 0512 (Initial value: 0255)
Range: 0000 to 0512 (Initial value: 0255)
Range: 0000 to 0255 (Initial value: 0100)
Range: 0000 to 0255 (Initial value: 0100)
Range: 0000 to 0255 (Initial value: 0100)
(1) Adjusting method using RS-232C
•
Get a personal computer with a COM port (RS-232C) equipped with WINDOWS 95/98/me/2000/xp and
a RS-232C crossing cable
a RS-232C crossing cable
•
Start up the set with the RS-232C cable connected.
•
Start up the terminal software.
(Freeware products available on the Internet can be used.)
(Freeware products available on the Internet can be used.)
•
Make setting as shown below.
Baud rate
: 9600
Data
: 8 bits
Parity
: None
Stop
: 1 bit
Flow control : None
•
If the above setting is made correctly, pressing the "ENTER" key on the PC will make "ERR" appear on
the terminal software.
the terminal software.
•
In this state, entering a command shown in the table bellow and pressing the "SET/ENTER" key will allow
you to make an adjustment.
you to make an adjustment.
If "OK" is displayed on the terminal software after the "ENTER" key is pressed, the command has been
entered successfully.
If "ERR" is displayed, enter the command again.
entered successfully.
If "ERR" is displayed, enter the command again.
Click on the first or last page to see other LC-30AD1E (serv.man7) service manuals if exist.