LC-30AD1E (serv.man6). removing of major parts - Sharp TV Service Manual (repair manual). Page 4

Read Sharp LC-30AD1E (serv.man6) Service Manual online

17
LC-30AD1E
 Precautions in handling the LCD panel
1. Handle the liquid crystal panel in a clean room (Humidity: 50% or more).
2. Be sure to wear an earth wristband.
3. Be careful not to drop and shock the liquid crystal panel.
4. Use an ionizer (within 30 cm).
23.Remove the four lock screws from the LCD panel.
24.Peel off the conductive sheet.
25.Detach the deflection sheet, prism sheet, diffusion sheet and diffusion panel.
26.Remove the two lock screws from ITO earth spring.
27.Remove the three lock screws from each of the top and bottom lamp holders, and detach the top and bottom lamp
holders.
28.Detach the lamp assembly from the lamp clip.
Lamp Clip (4 pcs.)
(LHLDZA085WJZZ)
Back Shield Ass'y
Reflection Sheet
Reflection Sheet
Lamp Fixing Holder (Bottom)
(LHLDZA084WJKZ)
Lamp Fixing Holder (Top)
(LHLDZA083WJKZ)
ITO Earth Spring
(MSPRP1220CEFW)
Diffusion Sheet
(PSHEPA110WJZZ)
Prism Sheet
(PSHEPA109WJZZ)
30" LCD Panel Unit
(RLCDTA026WJZZ)
Deflection Sheet
(PSHEPA108WJZZ)
Deflection Panel
(PCOVUA017WJZZ)
Lamp Fixing Holder (Top)
(LHLDZA083WJKZ)
Lamp Fixing Holder (Bottom)
(LHLDZA084WJKZ)
Lamp
(KLMP-A021WJZZ)
Condutive Sheet
28
25
27
24
23
26
27
Page of 4
Display