LC-26LE430E - Sharp TV Service Manual (repair manual). Page 2

Read Sharp LC-26LE430E Service Manual online

LC-19LE430E, LC-22LE430E, LC-26LE430E, LC-32LE430E 
2  
SAFETY PRECAUTION 
 
IMPORTANT SERVICE SAFETY PRECAUTION 
 
  
Service work should be performed only by qualified service technicians who are thoroughly familiar with all safety checks and the 
servicing guidelines which follow:
 
 
 WARNING 
1.  For continued safety, no modification of any circuit should be 
attempted. 
2.  Disconnect AC power before servicing.
 
 
CAUTION: 
FOR CONTINUED PROTECTION AGAINST A 
RISK OF FIRE REPLACE ONLY WITH SAME 
TYPE FUSE. 
42"         F901 (T6.3AH/250V) 
26"/32"   F901 (T5AH/250V)
 
 
 BEFORE RETURNING THE RECEIVER 
(Fire & Shock Hazard)
 
Before returning the receiver to the user, perform the following 
safety checks:
 
3.  Inspect all lead dress to make certain that leads are not pinched, 
and check that hardware is not lodged between the chassis and 
other metal parts in the receiver. 
4.  Inspect all protective devices such as non-metallic control knobs, 
insulation materials, cabinet backs, adjustment and compartment 
covers or shields, isolation resistor-capacitor networks, mechanical 
insulators, etc. 
5.  To be sure that no shock hazard exists, check for leakage current in 
the following manner. 
•   Plug the AC cord directly into a 220~240 volt AC outlet. 
•   Using two clip leads, connect a 1.5k ohm, 10 watt resistor paralleled 
by a 0.15µF capacitor in series with all exposed metal cabinet 
parts and a known earth ground, such as electrical conduit or 
electrical ground connected to an earth ground. 
•  Use an AC voltmeter having with 5000 ohm per volt, or higher, sen- 
sitivity or measure the AC voltage drop across the resistor. 
•  Connect the resistor connection to all exposed metal parts having a 
return to the chassis (antenna, metal cabinet, screw heads, knobs 
and control shafts, escutcheon, etc.) and measure the AC voltage 
drop across the resistor. 
All checks must be repeated with the AC cord plug connection 
reversed. (If necessary, a nonpolarized adaptor plug must be used 
only for the purpose of completing these checks.) 
Any reading of 1.05 V peak (this corresponds to 0.7 mA peak AC.) 
or more is excessive and indicates a potential shock hazard which 
must be corrected before returning the monitor to the owner.
 
 
 
DVM 
AC SCALE 
1.5k ohm 
10W 
 
 
 
0.15 µF 
TEST PROBE 
 
TO EXPOSED 
METAL PARTS 
 
 
 
 
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// 
SAFETY NOTICE  
Many electrical and mechanical parts in LCD color television have 
special safety-related characteristics. 
These characteristics are often not evident from visual inspection, 
nor 
can protection afforded by them be necessarily increased by using 
replacement components rated for higher voltage, wattage, etc. 
Replacement parts which have these special safety characteristics 
are identified in this manual; electrical components having such 
features are identified by “   ”  and shaded areas in the Replacement 
Parts List and Schematic Diagrams. 
 
For continued protection, replacement parts must be identical to those 
used in the original circuit. 
The use of a substitute replacement parts which do not have the same 
safety characteristics as the factory recommended replacement parts 
shown in this service manual, may create shock, fire or other hazards. 
 
 
 
 
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// 
 
 
 
CONNECT TO KNOWN 
EARTH GROUND 
Page of 127
Display