LC-26D44E (serv.man4). Adjustment - Sharp TV Service Manual (repair manual). Page 20

Read Sharp LC-26D44E (serv.man4) Service Manual online

LC-26D44E/S/RU-BK/GY
3 – 20
[6] Special features
* ERROR STANDBY CAUSE (Page 1/11)
The total time when the unit enters the standby due to operational error and cause of error are recorded on EEPROM as much as possible.
The values can be used to locate the fault for repair.
* EEP CLEAR (Page10/11)
Clear of process adjustment EEP value.
Page
Line
Item
Description
Remarks (adjustment detail, etc.)
8/11
[M GAMMA 1-3]
1
M GAMMA R 1
0
W/B adjustment, gradation 1R adjustment value
2
M GAMMA G 1
0
W/B adjustment, gradation 1G adjustment value
3
M GAMMA B 1
0
W/B adjustment, gradation 1B adjustment value
4
M GAMMA R 2
0
W/B adjustment, gradation 2R adjustment value
5
M GAMMA G 2
0
W/B adjustment, gradation 2G adjustment value
6
M GAMMA B 2
0
W/B adjustment, gradation 2B adjustment value
7
M GAMMA R 3
0
W/B adjustment, gradation 3R adjustment value
8
M GAMMA G 3
0
W/B adjustment, gradation 3G adjustment value
9
M GAMMA B 3
0
W/B adjustment, gradation 3B adjustment value
10
M GAMMA WRITE
OFF/ON
EEP writing of adjustment values
9/11
[M GAMMA 4-6]
1
M GAMMA R 4
0
W/B adjustment, gradation 4R adjustment value
2
M GAMMA G 4
0
W/B adjustment, gradation 4G adjustment value
3
M GAMMA B 4
0
W/B adjustment, gradation 4B adjustment value
4
M GAMMA R 5
0
W/B adjustment, gradation 5R adjustment value
5
M GAMMA G 5
0
W/B adjustment, gradation 5G adjustment value
6
M GAMMA B 5
0
W/B adjustment, gradation 5B adjustment value
7
M GAMMA R 6
0
W/B adjustment, gradation 6R adjustment value
8
M GAMMA G 6
0
W/B adjustment, gradation 6G adjustment value
9
M GAMMA B 6
0
W/B adjustment, gradation 6B adjustment value
10
M GAMMA WRITE
OFF/ON
EEP writing of adjustment values
10/11
[ETC]
1
EEP CLEAR
OFF/ON
Clear of all adjustment value
2
EEP CLEAR B
OFF/ON
Clear of adjustment value of B mode
3
STANDBYCAUSE RESET
OFF/ON
Reset of STANDBY CAUSE
4
AUTO INSTALLATION SW
0/1
1: * * * 0: * * *
5
OPTION 
0
6
COUNTRY
AUTO/EURO/UK
Destination setting
7
L ERR RESET
0
LAMP ERR RESET Initializatio of L_ERR
8
L ERR STOP
0/1
LAMP ERR Inhibit L_LRR detection
9
DTV CLR
ENTER
Clear of DTV setting
10
I2C-OFF
ENTER
I2C DATA execution
11/11
[COM-BIAS]
1
VCOM ADJ
63
INVERTER drive frequency setting
2
TEST PATTERN
0
INVERTER drive frequency setting
Page of 26
Display

Click on the first or last page to see other LC-26D44E (serv.man4) service manuals if exist.