LC-24LS240
Short CCT Protection Circuit
Short circuit protection is necessary for protecting chassis and main IC against damages when any 
Vcc supply shorts to ground. Protect pin should be logic high while normal operation. When there 
is a short circuit protect pin should be logic low. After any short detection, SW forces LEDs on LED 
card to blink.
For adapter case also below blocks are  necessary. 