LC-22SV2E (serv.man8). Troubleshooting table - Sharp TV Service Manual (repair manual). Page 4

Read Sharp LC-22SV2E (serv.man8) Service Manual online

23
LC-22SV2E
TROUBLE SHOOTING TABLE
 (Continued)
No picture
Check all the settings microprocessor's adjust process menu.
Is source GND 
normal?
Is CSCOM 
waveform 
normal?
Check FB4901, 
FB4902 and its
peripheral parts.
Check IC4702, 
IC4701, Q4701 
and their 
peripheral parts.
Check FB4562 
and its
peripheral parts.
Yes
No
No
Becomes
dark
No
Time passes,
becomes 
dark
Is gate GND 
normal?
Is gate clock
(GCK) normal?
Check FL4572, 
R4582 and gate 
aray peripheral 
parts.
Yes
No
Check IC4568 
and its
peripheral parts.
No
Is VEE-6V being 
outputted?
Is VGH+34V 
being 
outputted?
Check IC4565 
and its 
peripheral parts.
Yes
No
Is GSP 
waveform 
normal?
Check R4578 
and its
peripheral parts.
Yes
No
Becomes
white.
Is VSH+3.3V 
being 
outputted?
Is source clock 
normal?
Check IC4713 
and its 
peripheral parts.
Check R4563, 
IC4561 and 
their peripheral 
parts.
Check IC4907 
and gate aray 
peripheral parts.
Is output of LBR 
normal?
Yes
Yes
No
No
No
Vertical line 
output
Page of 6