LC-19D1EWH (serv.man4). Adjustment Procedure - Sharp TV Service Manual (repair manual). Page 20

Read Sharp LC-19D1EWH (serv.man4) Service Manual online

LC-19D1E/S-BK/WH
3 – 20
S4
 SOUND4
SP
HP
1
HPFEN
1
1
Setting of HPF ON/OFF except a HDMI input. Turn ON at 1.
2
HPFAPP
1
0
Setting of HPF 1st order IIR or 2nd order IIR except a HDMI input. 
1st at 0.  2nd at 1.
3
HPFCUT
2
0
Setting of cutoff frequency of HPF except a HDMI input. 245Hz at 
3, the larger number has big Fc. The 1st is only 3.7Hz.
4
LIMEN
1
0
Setting of ON/OFF of auto level control on the DAC side. ON at 1.
5
LIMDCY
11
3
Setting of decay (release) time of auto level control on the DAC 
side. The larger number is longer.
6
LIMATK
11
2
Setting of attack time of auto level control on the DAC side. The 
larger number is longer.
7
LIMLVL
5
0
Setting of limit level of the auto level control. -6dBFS at 5. -1dBFS 
at 0.
8
LIMBOOST
4
6
Setting of Boost level. 2dBUP at 2.
9
ALCSEL
0
0
Setting of ON/OFF of auto level control on the ADC side. The 
ADC side does not use it now because ALC (LIMEN)  is used at 
the DAC side.
10
ALCMAX
7
7
This is not used now.
11
ALCMIN
0
0
This is not used now.
12
ALCHDL
0
0
This is not used now.
13
ALCLVL
10
10
This is not used now.
14
ALCMOD
1
1
This is not used now.
15
ALCDCY
3
3
This is not used now.
16
ALCATK
3
3
This is not used now.
17
NGEN
0
0
Setting of ON/OFF of the noise gate on the ADC side. This is not 
used now. 
18
NGTH
0
0
TU
TUNER1
1
AFT UP
1.80
AFT Voltage initial level (ALL BAND)
2
AFT DOWN
1.20
AFT Voltage initial level (ALL BAND)
3
LSYNC
150
AFT Voltage initial level (HIGH BAND)
4
HSYNC
162
AFT Voltage initial level (HIGH BAND)
5
LSYNC2
150
AFT Voltage initial level (HIGH BAND)
6
HSYNC2
162
AFT Voltage initial level (HIGH BAND)
7
AVSYNC
1
AFT Voltage initial level (HIGH BAND)
TU
 TUNER2
1
AFT FARTIME
50
Channel preset time adjustment 1 
2
AFT NEARTIME
30
Channel preset time adjustment 2 
3
AFT NEARTIME
10
Channel preset time adjustment 3 
4
AFT 1STEPTIME
10
Channel preset time adjustment 4 
5
AFT CSYNCTIME
50
Channel preset time adjustment 5
6
SYNC  ON
10
Channel preset Synchronous judgment Count of a continuation 
accordance 
7
SYNC WIDTH
1
Channel preset Synchronous judgment Threhold level
8
AFT
2
Changeover of operation when AFT at the time of 1channel tuning 
9
MUTE  OFF  TIMING
0
Video mute reset, Sound mute reset timing  at the time of RF tun-
ing,
10
COLOR SYSTEM SEMI-AUTO
0
Oeration of the color system AUTO at the time of RF tuning 
D-1
DVP1
1
TAMP1 L
101
TAMP adjustment (for DVP-M2) Y lower level setting
2
YDATA
103 (variable) TAMP adjustment (for DVP-M2) data READ level
3
TAMP1 H
105
TAMP adjustment (for DVP-M2) Y upper level setting
4
TAMP ALL
OFF
TAMP adjustment (for DVP-M2/X/BE) set to ON when adjustting.
5
NTSC TAMP1
89
TAMP adjustment (for DVP-M2) (It is automatically set.)
6
PAL TAMP1
96
TAMP adjustment (for DVP-M2) setting
7
SECAM TAMP1
96
TAMP adjustment (for DVP-M2) (It is automatically set.)
D2-1
DVP2-1
1
IN1
0
Standard value 1
2
IN2
0
Standard value 2
3
IN3
0
Standard value 3
4
IN4
0
Standard value 4
5
IN5
102
Standard value 5
6
IN6
204
Standard value 6
Page
Line
Item
Description
Remarks (adjustment detail, etc.)
Page of 35
Display

Click on the first or last page to see other LC-19D1EWH (serv.man4) service manuals if exist.