26
LC-15M4E
VOLTAGE MEASUREMENT CONDITION:
1. Voltages at test points are measured at the
supply voltage of AC 120V.  Signals are fed by a
color bar signal generator for servicing purpose and
the above voltages are measured with a 20k ohm/
V tester.
WAVEFORM MEASUREMENT CONDI-
TION:
1. Waveforms at test points are observed at the supply
voltage of AC 120V.  Signals are fed by a color bar
signal generator for servicing purpose.
INDICATION OF RESISTOR & CAPACI-
TOR:
RESISTOR
1. The unit of resistance “
” is omitted.
(K=k
=1000 
,  M=M
).
(J= ± 5%, F= ± 1%, D= ± 0.5%)
noted.
 
C
 : Solid
W
 : Cement
 
S
 : Oxide Film
 
T
 : Special
 
N
 : Metal Coating
CAPACITOR
1. All capacitors are 
µ
(P=pF=
µµ
F).
noted.
(ML): Mylar
(TA): Tantalum
(PF): Polypro Film
(ST): Styrol
CAUTION:
This circuit diagram is original one,  therefore there may be a
slight difference from yours.
SAFETY NOTES:
1. DISCONNECT THE AC PLUG FROM THE AC
OUTLET BEFORE REPLACEING PARTS.
2. SEMICONDUCTOR HEAT SINKS SHOULD BE
REGARDED AS POTENTIAL SHOCK HAZARDS
WHEN THE CHASSIS IS OPERATING.
IMPORTANT SAFETY NOTICE:
PARTS MARKED WITH  “
å
 (
)   A R E
IMPORTANT FOR MAINTAINING THE SAFETY OF
THE SET.  BE SURE TO REPLACE THESE PARTS
WITH SPECIFIED ONES FOR MAINTAINING THE
SAFETY AND PERFORMANCE OF THE SET.