Read Sharp LC-10A3E (serv.man4) Service Manual online
10
11
12
13
14
15
16
17
18
19
19
LC-10A3E
DESCRIPTION OF SCHEMATIC DIA-
GRAM
GRAM
VOLTAGE MEASUREMENT CONDITION:
1. When the exclusive-use AC adapter is used, the colour
bar signal of colour bar generator for service is input to
get the normal screen. When the audio is minimized,
the voltage value is measured with the 20 k
get the normal screen. When the audio is minimized,
the voltage value is measured with the 20 k
Ω
/V tester.
WAVEFORM MEASUREMENT CONDITION:
1. When the exclusive-use AC adapter is used, the colour
density, lightness and colour hue are set to the center
position, and the signal of colour bar generator for
service is observed to get waveform.
The wave form test point is indicated with the mark
(
position, and the signal of colour bar generator for
service is observed to get waveform.
The wave form test point is indicated with the mark
(
) in the wiring diagram.
INDICATION OF RESISTOR & CAPACITOR:
RESISTOR
1. The unit of resistance “
1. The unit of resistance “
Ω
” is omitted.
(K=k
Ω
=1000
Ω
, M=M
Ω
).
2. All resistors are ± 5%, unless otherwise noted.
(J= ± 5%, F= ± 1%, D= ± 0.5%)
3. All resistors are Carbon type, unless otherwise noted.
C
: Solid
W
: Cement
S
: Oxide Film
T
: Special
N
: Metal Coating
CAPACITOR
1. All capacitors are mF, unless otherwise noted.
1. All capacitors are mF, unless otherwise noted.
(P=pF=mmF).
2. All capacitors are Ceramic type, unless otherwise
noted.
(ML) : Mylar
(ML) : Mylar
(TA) : Tantalum
(PF) : Polypro Film
(ST) : Styrol
CAUTION:
This circuit diagram is original one, therefore there may be a
slight difference from yours.
slight difference from yours.
IMPORTANT SAFETY NOTICE:
PARTS MARKED WITH “
å
” ( )ARE
IMPORTANT FOR MAINTAINING THE SAFETY OF
THE SET. BE SURE TO REPLACE THESE PARTS
WITH SPECIFIED ONES FOR MAINTAINING THE
SAFETY AND PERFORMANCE OF THE SET.
THE SET. BE SURE TO REPLACE THESE PARTS
WITH SPECIFIED ONES FOR MAINTAINING THE
SAFETY AND PERFORMANCE OF THE SET.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
A
B
C
D
E
F
G
H
I
J
LC-10A3E
LC-10A3E
20~21
å
AND SHADED COMPONENTS=SAFETY RELATED PARTS
Ë
MAIN Unit -1/2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
A
B
C
D
E
F
G
H
I
J
LC-10A3E
LC-10A3E
å
AND SHADED COMPONENTS=SAFETY RELATED PARTS
22~23
Ë
MAIN Unit -2/2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
A
B
C
D
E
F
G
H
I
J
LC-10A3E
LC-10A3E
24~25
å
AND SHADED COMPONENTS=SAFETY RELATED PARTS
Ë
TERMINAL Unit
å