Read Sharp DV-5937H (serv.man14) Technical Bulletin online
Sharp Electronics (UK) Limited
Reference WW191199-1
Revision 1
White – Carry out as required, Yellow – Carry out as required and whenever the unit comes in for service, Red – Carry out on all units
CTV991204
Month of Issue: November 1999
Classification: White
TELEVISION TECHNICAL BULLETIN
Page 1 of 1
MODELS
DV5932H
DV5935H
DV5937H
DV6635H
66AS06H
SYMPTOM Lack of width (no east/west correction) with severe cramping of the lower half of the
vertical scan
CAUSE C607 and L604.
ACTION Replace C607 and L604.
REF NO
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
C607
Capacitor, 0.56uF 250V
RC-FZ6564BMNJ
AE
L604
Coil
RCILP0104CEZZ
AG
Display