76FW-54H. DA100 Repair Notes - Sharp TV Service Manual (repair manual). Page 8

Read Sharp 76FW-54H Service Manual online

DA100 (50Hz) and DA50W Chassis – Repair Notes 
 
Page 8 of 80 
Sharp Electronics (UK) Limited - May 2003 
 
Revision 3
Product Specifications 
The basic chassis comes with NICAM and fast text as standard and can drive CRT’s from 56 to 76cm in both 4:3 
and 16:9 formats.  The only 4:3 sets that use this chassis are the 59ESD7H and 66ESD7H, both of which are 
Dolby Pro-Logic models. 
All variants of this chassis are fitted with three SCART sockets on the rear of the board – composite video, S-
Video and RGB can be fed into these sockets. In addition to this, some models have front AV sockets (phono and 
S-Video). 
All Dolby Pro-Logic models have full functionality, allowing connection of separate speakers for front left, front 
right, rear left, rear right and sub-woofer.  In the Pro-logic mode (once correctly set up in the user menu) the 
internal speakers – left, right and centre - become the centre channel. 
 
Model 
Screen 
Size 
Fast Text 
NICAM 
Pro-Logic 
Double 
Copper  
CRT Types 
Production 
28HW53H 66cm 
 
Thomson 
2001 to 2002 
32HW53H 76cm 
 
Thomson 
2001 to 2002 
56FW53H 56cm 
 
Philips/Thomson 
1999 to 2002 
66FW53H 66cm 
 
 
Thomson/LG 
1999 to 2001 
66FW54H 66cm 
 
Thomson/LG 
1999 t0 2001 
66FW54H 66cm 
 
Thomson/LG 
2000 to 2002 
66GF63H 66cm 
 
Philips/Thomson 
2000 to 2002 
66GF64H 66cm 
Philips 
2000 to 2002 
76FW53H 76cm 
 
 
Thomson/LG 
1999 to 2001 
76FW54H 76cm 
 
Thomson/LG 
1999 to 2001 
76FW54H 76cm 
 
Thomson/LG 
2000 to 2002 
76GF63H 76cm 
 
Philips 
2000 to 2002 
76GF64H 76cm 
Philips 
2000 to 2002 
 
In some FW and GF models, and in all HW models, an earth plane was added to the top surface of the PWB 
(double copper), this is green in colour.  This reduces interference and the possible corruption of the NVM 
caused by power supply variations and CRT discharges.  It is possible to identify these chassis as the fourth digit 
of the serial number starts with the number 5.  
In later FW sets, a power factor module was fitted as a separate PWB.  This was connected between the output 
of the mains bridge rectifier and the main smoothing block.  Its function is to ensure that the current/voltage 
draw from the mains is kept in sync.  This eliminates ‘spikes’ or ‘troughs’ in the mains voltage waveform which 
keeps the electricity suppliers happy.  
Note that the first three digits before the serial number are in fact the month and year of manufacture, i.e. 
201 
512112 is January 2002. 
Page of 80
Display

Click on the first or last page to see other 76FW-54H service manuals if exist.