66GF-64 (serv.man2). DA100 Repair Notes - Sharp TV Service Manual (repair manual). Page 24

Read Sharp 66GF-64 (serv.man2) Service Manual online

DA100 (50Hz) and DA50W Chassis – Repair Notes 
 
Page 24 of 80 
 
 
 
Figure 19: Location of Centre Speaker 
PWB 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 20: Location of 
Components on the CRT PWB 
 
 
 
 
 
 
 
 
 
When the avalanche diode is fitted, only four components generally need to be replaced (D735, Q601, IC705 and 
C720), this is because it prevents further damage to the circuitry should the power supply be kept running.  
Sharp produce a kit that contains these four items - use the part number FWSERVKIT01// 
 
If the set is operated for prolonged periods without the avalanche diode fitted, then damage will occur to other 
parts of the circuit.  The CRT PWB suffers normally all the electrolytic capacitors have to be replaced if this is 
the case.  The moral is, DO NOT run the set when high HT is present. 
Sharp Electronics (UK) Limited - May 2003 
 