66CS03H
SYMPTOM Inter-station interference on channels 55, 59 and 65.
CAUSE
Cross interference between adjacent PWB tracks.
ACTION
Eliminate SMD jumper J8 and add jumper from pin 4 to pin 9 of plug FA.
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
Jumper
Wire Cable
VW7UGB0-035AA
AA
Display

Download Sharp 66DS-05H (serv.man46) Technical Bulletin

Here you can read online and download Sharp 66DS-05H (serv.man46) Technical Bulletin in PDF. 66DS-05H (serv.man46) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp 66DS-05H (serv.man46) CTR. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.