Read Sharp 37VT-24H (serv.man7) Technical Bulletin online
CTV2000 01 05
Month of Issue: January 2000
Classification: White
TELEVISION TECHNICAL BULLETIN
Page 1 of 1
Sharp Electronics (UK) Limited
Reference AVW2000100-2
Revision 1
White – Carry out as required, Yellow – Carry out as required and whenever the unit comes in for service, Red – Carry out on all units
MODELS
37VT24H
SYMPTOM Intermittent or no television section operation.
CAUSE
Trip circuit operating intermittently due to R626 going high or open circuit in the trip
detection circuit.
detection circuit.
ACTION
Replace R626 with a 1.2M, 0.25W resistor.
This resistor should be obtained from a local supplier.