37GT-27H (serv.man16) - Sharp TV Service Manual (repair manual). Page 24

Read Sharp 37GT-27H (serv.man16) Service Manual online

24
37GT-27H
Waveform Measurement Condition:
1. Test Equipment: DIGITAL SLPE LECROY.
2. Test Conditions: CH-12;  COLOUR BARS; 70dB FROM RF INPUT
3. TV  Condition: PICTURE AND AUDIO : SETTINGS 
à 
FACTORY PRESETS
1. The unit of resistance «ohm»is omitted (K=1000
ohms. M= Megaohm).
2. All resistors are 1/8 watt. unless otherwise noted.
3. All capacitors are 
µ
F, unless otherwise noted (P=
µµ
F).
4. The capacitor with Part No. RC-FZ9XXXBMNJ is
designed to with stand 63V.
5. The capacitor with Part No. RC-FZ4XXXBMNJ is
designed to with stand 50V.
NOTE:
SERVICE PRECAUTION:
DESCRIPTION OF SCHEMATIC DIAGRAMS
SAFETY NOTE:
1. DISCONNECT THE AC PLUG FROM THE AC
OUTLET BEFORE REPLACING PARTS.
2. SEMICONDUCTOR HEAT SINKS SHOULD BE
REGARDED AS POTENTIAL SHOCK HAZARDS
WHEN THE CHASSIS IS OPERATING.
IMPOTANT SAFETY NOTE:
PARTS MARKED WITH  «
»  (
 
                      
) ARE
IMPORTANT FOR MAINTAINING THE SAFETY
OF THE SET. BE SURE TO REPLACE THESE
PARTS WITH SPECIFIED ONES FOR
MAINTAINING THE SAFETY AND PERFORMAN-
CE OF THE SET.
CAUTION
This circuit diagram is original one,
therefore there may be slight difference
from yours.
THE AREA ENCLOSED BY THIS LINE (           )
IS DIRECTLY CONNECTED WITH AC MAINS
VOLTAGE.
WHEN SERVICING THE AREA, CONNECT AN
ISOLATING TRANSFORMER BETWEEN TV
RECEIVER AND AC LINE TO ELIMINATE
HAZARD OF ELECTRIC SHOCK.
Vp PRIMARY
Vp SECUNDARY
1
2
3
Waveform:
H-CONTROL
Page of 44
Display

Click on the first or last page to see other 37GT-27H (serv.man16) service manuals if exist.