37GQ-20 (serv.man6). without parts listing (tentative) - Sharp TV Service Manual (repair manual). Page 10

Read Sharp 37GQ-20 (serv.man6) Service Manual online

10
37GQ-20H
1. HOR  POS
a) Receive Philips pattern signal.
b) When 
  
 button is pressed, picture moves to the left.
c) When 
 
 
 button is pressed, picture moves to the right.
d) Adjust the horizontal location to obtain picture centering (Fig.1).
GEOMETRY ADJUSTMENT PROCEDURE
2. VERT POS
a) Receive Philips pattern signal.
b) When 
  
 button is pressed, picture moves up.
c) When 
 
 
 button is pressed, picture moves down.
d) Adjust the vertical location to obtain picture centering (Fig.2).
3. VERT AM
a) Receive Philips pattern signal.
b) When 
  
 button is pressed, vertical size of picture increases.
c) When 
 
 
 button is pressed, vertical size of picture decreases.
d) Adjust the vertical size to obtain picture overscan (Fig.3).
The following adjustments are required when the Picture Tube or IC801 are replaced, or
may be necessary after adjustment of the G2 voltage.
1. «B-GAIN», «G-GAIN»
a) Adjust G2.
b) Tune a grey scale pattern.
c) Adjust colour to minimum.
d) Fix R-GAIN value to 50.
e) Position colourmeter in the the left point of Fig.4.
f) Using brightness and contrast buttons, select a luminance of 
120 nits.
g) Operate again in Service Mode and select location B-GAIN and
G-GAIN to obtain colour   coordinates:
X = 0.290 
±
 0.015
Y = 0.284 
±
 0.015
h) Exit Service Mode and check colour coordinates «X» and «Y» at 20 and 120 nits. It may be
necessary to repeat the same procedure or re-adjust the cuts as show the be below one.
2. «G-DC», «R-DC»
a) Adjust G2, in the case that it has not been made previously.
b) Tune a grey scale pattern.
c) Adjust colour to minimum.
e) Position colourmter in the the right point of Fig.4.
f) Using brightness and contrast buttons, select a luminance of 
20 nits.
g) Operate again in Service Mode and select location G-DC and R-DC to obtain colour
coordinates:
X = 0.290 
±
 0.015
Y = 0.284 
±
 0.015
h) Exit Service Mode and check colour coordinates «X» and «Y» at 20 and 120 nits. It may be
necessary to repeat the same procedure or the previous one.
COLOUR ADJUSTMENT (BKGD) PROCEDURES
NOTE: Locations «R» alter «X» coordinates; «G» alter «Y» coordinates; «B» alter «X» and «Y»
coordinates.
Fig. 2
Fig. 1
Fig. 3
Fig. 4
    3        7        4        0
6   5   4    3   2    1   0
(0: Black ... 7: White)
Gain point
DC point
Page of 22
Display