Read Sharp 37DT-25H (serv.man29) Technical Bulletin online
Sharp Electronics (UK) Limited CE Technical Support Group
Originator
$Y:
$Y:
Supervisor
Approval Date / / Reference GE74000X
White - Carry out as required Yellow - Carry out as required and whenever unit comes in for service Red - Carry out on all units
CTV980201
Month of Issue : February 1998
Classification :
Classification :
White
TELEVISION TECHNICAL BULLETIN
Page 2 of 2
To block the tuning mode NVM address 0B has to be changed as follows.
Model
Nominal Value
Hotel Value
37DM23H
F8
FC
37DT25H
F8
FC
51DT25H
F8
FC
To set the maximum volume level, change NVM address 0E as follows.
Maximum volume
FF
90% volume ( approximately )
E7 to EF
80% volume ( approximately )
CF to DF
73% volume ( approximately )
BF
62% volume ( approximately )
9F to BF
50% volume ( approximately )
7F
When the hotel mode has been set, turn off the receiver at the mains switch, turn back on
and check all functions.
and check all functions.
Display