TELEVISION TECHNICAL BULLETIN
Page 1 of 1
MODELS
37DM23H
37DT25H
51DT25H
Common faults on the CA1 Chassis
Fault
Reason
Possible Cause
No teletext
Low video input to pin 30 of IC1001 (should be 2.5V).
Q201 or Q801
Buzz on sound
Noise on audio IF signal or AFT VCO adjustment
incorrect
incorrect
Q801 or poor adjustment of the AFT
VCO
VCO
Erratic start up problems
Noise corrupting operation of IC1001/201
See Technical Bulletin CTV981205
Vertical stage problems
Various component failures. Note that as the vertical
output stage is DC coupled, a problem at the start of the
stage can have a dramatic effect on the output.
output stage is DC coupled, a problem at the start of the
stage can have a dramatic effect on the output.
Check all components in the vertical
stage, paying particular attention to
R507/8/22, C510/2/14 and C713
stage, paying particular attention to
R507/8/22, C510/2/14 and C713
No start up
Power supply failure
Q702 and/or D718 short circuit
Dead set
Power supply running, but no picture and sound – reset
pulse problems
pulse problems
Q704 and/or Q1012
Low HT (40V)
Fedback control for the power supply incorrect
Check components around the opto-
coupler
coupler
Note that the CA1\CA10 chassis training course notes are available on the Sharp Electronics (UK) Limited Web Site
(
(
www.tradenet.sharp.co.uk/tech
) under the models fitted with these chassis - grouped under the Service Manual
heading. These notes contain in depth details on circuit operation. Please refer to these while fault finding.
If you have a fault to add to the above list, please do no hesitate to contact Sharp Technical Support via the Hot Line
telephone number.
telephone number.