11
21HT-15H
COLOUR ADJUSTMENT PROCEDURE 
 
The following adjustments should only be carried out when the CRT or IC801 are replaced. 
 
NOTES:  
 
This adjustment must be done after warming up the unit for 30 minutes or longer with a beam current over 700 µA. 
 
The red value «DRI-RS» should be fixed to 42. (Refer to “How to access service mode” section).  
 
«DRI-GS» adjustment alters  “Y” co-ordinate. 
 
«DRI-BS» adjustment alters  “X” and “Y” co-ordinates. 
 
ADJUSTMENT METHOD 1 (using the signal generator, varying the picture signal) 
 
1.   Adjust G2. 
2.  Input a white pattern with burst signal from SCART. 
3.  Position the colorimeter in the centre of screen. 
4.  Adjusting input signal level, select a luminance of 70 nits. 
5.  Operate again in “service mode“ and select «DRI-GS» and/or  «DRI-BS» locations to obtain colour co-ordinates: 
 
 
MODEL 
X 
Y Screen 
temperature 
21HT-15H 
0.290 
±
 0.015 
0.284 
±
 0.015 
8900º K-20 MPCD 
 
 
6.  Re-set the TV with the mains switch button (
) to store the adjustment and exit service mode
7.  Check colour co-ordinates  “X” and “Y” at 20 a 120 Nits. It may be necessary to repeat the same procedure to obtain the 
above values. 
 
 
ADJUSTMENT METHOD 2 (using the signal generator, with a fixed picture signal) 
 
1.   Adjust G2. 
2.  Tune a white pattern with burst signal. 
3.  Operate in “service mode”: 
4.  Using  «SUB-CON», select a luminance of 70 nits. 
5.  Operate again in “service mode“ and select «DRI-GS» and/or  «DRI-BS» locations to obtain colour co-ordinates: 
 
 
MODEL 
X 
Y Screen 
temperature 
21HT-15H 
0.290 
±
 0.015 
0.284 
±
 0.015 
8900º K-20 MPCD 
 
6.  Select  «SUB-CON». Return data to “63”. 
7.  Re-set the TV with the mains switch button (
) to store the adjustment and exit service mode
8.  Check colour co-ordinates  “X” and “Y” at 20 a 120 Nits. It may be necessary to repeat the same procedure to obtain the 
above values. 
 
Page of 12