15FS-25H. Tester Download - Sharp TV Specification (repair manual). Page 122

Read Sharp 15FS-25H Specification online

MX-2300/2700 N/G  SIMULATION  7 – 15
 
6-2
Purpose
Operation test/check
Function (Purpose) Used to check the operations of each fan
motor and its control circuit.
Section
Other
Item
Operation
Operation/Procedure
1) Select the item to be checked with the buttons on the touch
panel.
2) Press [EXECUTE] button.
The selected load operation is performed.
When [EXECUTE] button is pressed, the operation is termi-
nated.
 
6-3
Purpose
Operation test/check
Function (Purpose) Used to check the operations of the primary
transfer unit and the related circuit. 
Section
Process (Transfer)
Item
Operation
Operation/Procedure
1) Press [EXECUTE] button.
2) The load operation is started. (Separation operation: BLACK
→ COLOR → FREE  Stops at each position for 5 sec.) During
the operation, the current position is displayed.
 
7
 
7-1
Purpose
Setting
Function (Purpose) Used to set the operating conditions of
aging.
Section
Other
Item
Operation
Operation/Procedure
1)
Select the target to be set with buttons on the touch panel.
2)
Press [EXECUTE] button.
The machine is rebooted in the aging mode. 
The contents set with this simulation are retained until the
power is turned OFF. 
 
7-6
Purpose
Setting
Function (Purpose) Used to set the intermittent aging cycle.
Section
Other
Item
Operation
Operation/Procedure
1)
Enter the intermittent aging cycle (unit: sec) with 10-key.
2)
Press [OK] button.
The time entered in procedure 1) is set.
POFM
Paper exit cooling fan motor (* POFM_U, POFM_F, and 
POFM_R are driven at the same time.)
OZFM
Ozone fan motor
PSFM
Power cooling fan motor
BLACK
Black mode position
Black mode position
→ COLOR mode position
→ Drum separation position
→ Shift to the black mode 
position is repeated.
COLOR
COLOR mode position
FREE
Drum separation position





SIMULATION NO.06̆02
TEST
FAN LOAD SETUP
 
POFM
OZFM
PSFM
1/1
EXECUTE
0
CLOSE
0
SIMULATION NO.06̆03
TEST
TRANSFER LOAD CHECK
EXECUTE
POSITION
̆̆
:
1/1
CLOSE
AGING
Aging operation setup
INTERVAL
Intermittent setup
MISFEED DISABLE
JAM detection enable/disable setup
FUSING DISABLE
Fusing operation enable/disable setup
WARMUP DISABLE
Warm-up disable setup
DV CHECK DISABLE
DV unit detection enable/disable setup
SHADING DISABLE
Shading disable setup
CCD GAIN FREE
CCD gain adjustment free setup
Item
Item
Set range
Default value
A
CYCLE TIME(SEC)
1 to 900
3
SIMULATION NO.07̆01
TEST
AGING TEST SETTING
 
AGING
INTERVAL
MISFEED DISABLE
FUSING DISABLE
WARMUP DISABLE
DV CHECK DISABLE
1/1
EXECUTE
0
SHADING DISABLE
CCD GAIN FREE
CLOSE
0
A:
A㧦 3
CYCLE TIME(SEC)
SIMULATION NO.07-06
INTERVAL AGING CYCLE TIME SETUP
3
1㨪 900 㨉
OK
TEST
CLOSE
Page of 127
Display