XV-Z9000E (serv.man3). Service Manual - Part 2 - Troubleshooting (32-48) - Sharp Projector Service Manual (repair manual). Page 10

Read Sharp XV-Z9000E (serv.man3) Service Manual online

41
XV-Z9000U/E
NO
YES
YES
Checking the SOG circuit
Is the composite sync 
signal played back timely?
Measure the signal at 
TL8136 on the 
oscilloscope.
NO
Is there the Y signal 
including the sync signal?
Measure the land of C8069 
on the oscilloscope.
Go to “Checking the input 
signal settings”.
SOG sync separation 
circuit defective.
Input PWB defective.
There is no problem with 
the SOG circuit. End.
NO
Checking the on-screen 
display.
Go to “Checking the GA4 
peripheral circuits”.
Get the flash ROM 
reprogrammed.
Carry out the output line 
adjustment in the 
adjustment process.
Is the on-screen display 
color as specified?
YES
0
Page of 17