Read Sharp XV-Z9000E (serv.man20) Technical Bulletin online

LV060
Sharp Electronics (UK) Ltd., Technical Services Group
1. Model
XVZ9000E
2. Description
Improper operation of the motorised projection screen when the cooling fan has stopped
after the projector is turned off.
3. Cause
False trigger pulse (about 5V) is outputted on the DC12V OUTPUT terminal of the projector
when the cooling fan has stopped after the projector is turned off.
4. Servicing
If you receive a service call regarding this please change resistors R2869 and R2875.
Ref. No.
Part code
Description
Price code
R2869
VRN-CY1JF183D
Resistor, 18Ω
AA
R2875
VRN-CY1JF222D
Resistor, 2.2Ω
AB
FALSE TRIGGER PULSE OUTPUT ON DC 12V
OUTPUT TERMINAL
TECHNICAL BULLETIN
Date:
02 December 2002
Model: XVZ9000E
Ref.:
003
Colour: White
Page:
1 of 1
Display

Download Sharp XV-Z9000E (serv.man20) Technical Bulletin

Here you can read online and download Sharp XV-Z9000E (serv.man20) Technical Bulletin in PDF. XV-Z9000E (serv.man20) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp XV-Z9000E (serv.man20) Projector. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.