XV-Z3100 (serv.man4). Electrical Adjustment - Sharp Projector Service Manual (repair manual). Page 3

Read Sharp XV-Z3100 (serv.man4) Service Manual online

      XV-Z3100U/XV-Z3100/XV-Z3300/DT-510
4 – 3
Calling and quitting the process mode with the control keys on this model.
* Although it is possible for the process OUT to exit using the process menu, the IN/OUT toggle command is also available considering the existing
specification.
1) Calling and quitting
With the menu not displayed, press the "ENTER", "ENTER", "Right", "Left", "ENTER", "ENTER" and "MENU" keys on the remote control or on the
main unit.
2) Others
Press the S6213 process key (toggle) on the main PWB to call and quit the process menu.
NOTE: When adjusting in the process mode, set a signal with a vertical frequency of 60 Hz or no signal. (May not be properly adjusted with other sig-
nals.)
Resetting the lamp timer for this model
1) Resetting procedure
In Stand-by, run this command to clear the operating time of the lamp to 0 and turn on the power.
Press and hold "
 ", "ENTER", and "MENU", and then press the "STANDBY/ON" key of the set.