XV-Z200E (serv.man29). Complete service manual - Sharp Projector Service Manual (repair manual)

xv-z200e (serv.man29) service manual
Model
XV-Z200E (serv.man29)
Pages
116
Size
10.33 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / Complete service manual
File
xv-z200e-sm29.pdf
Date

Read Sharp XV-Z200E (serv.man29) Service Manual online

XV-Z200U/E, XV-Z201E
DT-300
In the interests of user-safety (Required by safety regulations in some countries) the set should be re-
stored to its original condition and only parts identical to those specified should be used.
MODELS
MODELLE
XV-Z200U/E
XV-Z201E
DT-300
THEATOR PROJECTOR
THEATOR PROJEKTOR
Im lnteresse der Benutzersicherheit (erforderliche Sicherheitsregeln in einigen Ländern) muß das Gerät in seinen
Originalzustand  gebracht werden.  Außerdem dürfen für die spezifizierten Bauteile nur identische Teile verwendet
werden.
SERVICE MANUAL
SERVICE-ANLEITUNG
SHARP CORPORATION
1st Edition
2
XV-Z200U/E, XV-Z201E
DT-300
CONTENTS
Page
Page
INHALT
Seite
Seite
• SPECIFICATIONS ............................................. 3
• IMPORTANT SERVICE SAFETY
NOTES .............................................................. 4
• NOTE TO SERVICE PERSONNEL ................... 5
• OPERATION MANUAL ..................................... 8
• DIMENSIONS ................................................. 12
• REMOVING OF MAJOR PARTS ..................... 13
• THE OPTICAL UNIT OUTLINE ...................... 19
• RESETTING THE TOTAL LAMP TIMER ......... 20
• ELECTRICAL ADJUSTMENT ......................... 22
• UPGRADING THE VERSION ......................... 27
• TROUBLE SHOOTING TABLE ....................... 31
• CHASSIS LAYOUT .......................................... 40
• BLOCK DIAGRAM .......................................... 42
• OVERALL WIRING DIAGRAM ........................ 44
• DESCRIPTION OF SCHEMATIC DIAGRAM .. 48
• WAVEFORMS ................................................. 49
• SCHEMATIC DIAGRAM .................................. 50
• PRINTED WIRING BOARD ASSEMBLIES ..... 88
• PARTS LIST
Ë 
ELECTRICAL PARTS ................................. 96
Ë 
CABINET AND MECHANICAL PARTS .... 110
Ë
 ACCESSORIES PARTS ............................ 136
Ë
 PACKING PARTS ...................................... 136
• PACKING OF THE SET ................................ 137
• TECHNISCHE DATEN .................................... 43
• HINWEISE FÜR DAS
WARTUNGSPERSONAL ................................ 44
• BEDIENUNGSANLEITUNG ............................ 46
• ABMESSUNGEN ............................................ 54
• ENTFERNEN DER HAUPTTEILE .................. 55
• RÜCKSTELLEN DES
LAMPENBETRIEBSEIT-TIMERS ................... 59
• BESCHREIBUNG DER OPTIK-INHEIT .......... 60
• ELEKTRISCHE EINSTELLUNG ..................... 62
• AKTUALISIERUNG DER VERSION ............... 70
• FEHLERSUCHTABELLE ................................ 74
• CHASSIS-ANORDNUNG ............................... 80
• BLOCKSCHALTBILD ...................................... 82
• GESAMTSCHALTPLAN .................................. 84
• BESCHREIBUNG DES SCHEMATISCHEN
SCHALTPLANS .............................................. 86
• WELLENFORMEN .......................................... 87
• SCHEMATISCHER SCHALTPLAN ................. 88
• LEITERPLATTENEINHEITEN ....................... 115
• ERSATZTEILLISTE
Ë
 ELEKTRISCHE BAUTEILE ....................... 122
Ë
 GEHÄUSE UND MECHANISCHE
    BAUTEILE ................................................. 132
Ë
 ZUBEHÖRTEILE ....................................... 136
Ë
 VERPACKUNGSTEILE ............................. 136
• VERPACKEN DES GERÄTS ........................ 137
3
XV-Z200U/E, XV-Z201E
DT-300
Specifications
This unit has some inactive pixels within acceptable
tolerances which may result in inactive dots on the picture
screen. This will not affect the picture quality or the life
expectancy of the unit. If you have any questions about this
matter, please call toll free 1-877-DTV-SHARP (1-877-388-
7427).
U.S.A. ONLY
Product type
Models
Video system
Display method
DLP panel
Lens
Projection lamp
Video input signal
S-video input signal
Component input signal
(INPUT 1)
Component input signal
(INPUT 2)
Horizontal resolution
RGB input signal
Pixel clock
Vertical frequency
Horizontal frequency
Computer control signal
Rated voltage
Input current
Rated frequency
Power consumption
Heat dissipation
Operating temperature
Storage temperature
Cabinet
I/R carrier frequency
Dimensions (approx.)
Weight (approx.)
Supplied accessories
Replacement parts
Projector
XV-Z200U/DT-300/XV-Z200E/XV-Z201E
PAL/PAL 60/PAL-M/PAL-N/SECAM/NTSC 3.58/NTSC 4.43
DTV 480I/480P/720P/1080I
DLP chip, RGB optical shutter method
Panel size: 0.6
Display method: Single Panel Digital Micromirror Device (DMD™) by Texas Instruments
Drive method: Digital Light Processing (DLP™)
No. of dots: 589,824 dots (1,024 [H] 
 576 [V])
1–1.2
 zoom lens, F1.75–2.04 f=28.0–33.5 mm
210 W/168 W SHP lamp
RCA Connector: VIDEO (INPUT 4), composite video, 1.0 Vp-p, sync negative, 75 
terminated
4-pin Mini DIN connector (INPUT 3)
Y (luminance signal): 1.0 Vp-p, sync negative, 75 
 terminated
C (chrominance signal): Burst 0.286 Vp-p, 75 
 terminated
RCA Connector
Y: 1.0 Vp-p, sync negative, 75 
Ω 
 terminated
P
B
: 0.7 Vp-p, 75 
Ω 
 terminated
P
R
: 0.7 Vp-p, 75 
Ω 
 terminated
29-pin connector
DVI input signal: Digital 250–1,000 mV 50 
                           Analog 0.7 Vp-p 75 
Y: 1.0 Vp-p, sync negative, 75 
Ω 
terminated
P
B
: 0.7 Vp-p, 75 
Ω 
 terminated
P
R
: 0.7 Vp-p, 75 
Ω 
 terminated
520 TV lines (NTSC 3.58 input)
DVI-I terminal
<Digital>
Input impedance
50 
Input level
250-1000 mV
<Analog>
Input impedance
75 
Input level
0.7 Vp-p
<Synchronization signal>
Separate sync/Composite sync
Input level
TTL level
Input impedance
1 K
Green on sync
Input level (Synchronizing input)
0.286 Vp-p
Input impedance
75 
12–80 MHz
43–75 Hz
15–70 kHz
9-pin D-sub connector (RS-232C Port)
AC 100–240 V
3.2 A
50/60 Hz
285 W
1,070 BTU/hour
41
°
F to 95
°
F (
5
°
C to 
35
°
C)
4
°
F to 140
°
F (
20
°
C to 
60
°
C)
Plastic
38 kHz
14
1
2
 (W) 
 6
9
16
 (H) 
 12
7
8
 (D) (368 
 153.8 
 327 mm) (including swivel stand)
14
1
2
 (W) 
 4
5
8
 (H) 
 12
7
8
 (D) (368 
 118 
 327 mm) (main body only)
10.1 lbs. (4.6 kg) (including swivel stand)
9.0 lbs. (4.1 kg) (main body only)
Remote control, Two AA size batteries, Power cord, Terminal cover, Lens cap (attached
on the body), Operation manual, Screws for terminal cover
Lamp unit (Lamp/cage module) (BQC-XVZ200++1), Remote control
(RRMCGA218WJSA), AA size batteries, Power cord (QACCDA007WJPZ), Terminal
cover (GCOVAA116WJKB), Lens cap (CCAPHA004WJ01), Operation manual (TINS-
B005WJZZ), Screws for terminal cover (XBBSN40P10000)
This SHARP projector uses a DMD chip. This very
sophisticated chip contains 589,824 pixels. As with any high
technology electronic equipment such as large screen TVs,
video systems and video cameras, there are certain
acceptable tolerances that the equipment must conform to.
Specifications are subject to change without notice.
×
×
×
×
×
×
×
×
4
XV-Z200U/E, XV-Z201E
DT-300
WARNING
1. For continued safety,  no modification of any circuit
should be attempted.
2. Disconnect AC power before servicing.
BEFORE RETURNING THE PROJECTOR:
(Fire & Shock Hazard)
Before returning the projector to the user,  perform
the following safety checks:
1. Inspect lead wires are not pinched between the chassis
and other metal parts of the projector.
2. Inspect all protective devices such as non-metallic
control knobs, insulating materials, cabinet backs,
adjustment and compartment covers or shields,
isolation resistor-capacity networks, mechanical
insulators, etc.
3. To be sure that no shock hazard exists, check for
current leakage in the following manner:
»
Plug the AC cord directly into a 120-volt AC outlet,
(Do not use an isolation transformer for this test).
»
Using two clip leads, connect a 1.5k ohm, 10 watt
resistor paralleled by a 0.15µF capacitor in parallel
between all exposed metal cabinet parts and earth
ground.
»
Use an AC voltmeter with sensitivity of 5000 ohm per
volt.,  or higher,  sensitivity to measure the AC voltage
drop across the resistor (See Diagram).
»
All checks must be repeated with the AC plug
connection reversed.  (If necessary,  a non-polarized
adapter plug must be used only for the purpose of
completing these checks.)
Any reading of 0.3 volts RMS (this corresponds to 0.2
milliamp. AC.) or more is excessive and indicates a
potential shock hazard which must be corrected before
returning the unit to the owner.
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
SAFETY NOTICE
Many electrical  and  mechanical parts in Projector have
special safety-related characteristics.
These characteristics are often not evident from visual
inspection, nor can protection afforded by them be
necessarily increased by using replacement components
rated for higher voltage, wattage, etc.
Replacement parts which have these special safety
characteristics are identified in this manual; electrical
components having such features are identified  by “
å
and  shaded  areas in the Replacement Parts Lists and
Schematic Diagrams.  For continued protection,
replacement parts must be identical to those used in
the original circuit.  The use of a substitute replacement
parts which do not have the same safety characteristics
as the factory recommended replacement parts shown
in this service manual, may create shock,  fire or other
hazards.
AVIS POUR LA SECURITE
De nombreuses pièces, électriques et mécaniques, dans
les projecteur à présentent des caractéristiques spéciales
relatives à la sécurité,  qui ne sont souvent pas évidentes
à vue.
Le degré de protection ne peut pas être nécessairement
augmentée en utilisant des pièces de remplacement
étalonnées pour haute tension, puissance,  etc.
Les pièces de remplacement qui présentent ces
caractéristiques sont identifiées dans ce manuel;
les pièces électriques qui présentent ces particularités
sont identifiées par la marque “
å
” et hachurées dans la
liste des pièces de remplacement et les diagrammes
schématiques.  Pour assurer la protection, ces pièces
doivent être identiques à  celles  utilisées dans le circuit
d’origine.  L’utilisation de pièces qui n’ont pas les mêmes
caractéristiques que les pièces recommandées par l’usine,
indiquées dans ce manuel, peut provoquer des
électrocutions, incendies ou autres accidents.
WARNING: The bimetallic component has the primary
conductive side exposed. Be very careful in
handling this component when the power is on.
AVERTISSEMENT: La composante bimétallique dispose du
conducteur primaire dénudé. Faire attention
lors de la manipulation de cette
composante sous tension.
AC
VOLTMETER
1.5k ohm  (10W)
0.15
µ
F
TEST PROBE
TO EXPOSED
METAL PARTS
CONNECT  TO  KNOWN
EARTH GROUND 
IMPORTANT SERVICE SAFETY NOTES
Ë
Service work should be performed only by qualified service technicians who are
thoroughly familiar with all safety checks and servicing guidelines as follows:
Page of 116
Display

Download Sharp XV-Z200E (serv.man29) Service Manual (Repair Manual)

Here you can read online and download Sharp XV-Z200E (serv.man29) Service Manual in PDF. XV-Z200E (serv.man29) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp XV-Z200E (serv.man29) Projector. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.