XV-Z12000. Version 1.3 - Sharp Projector Handy Guide. Page 47

Read Sharp XV-Z12000 Handy Guide online

Electrical Adjustments
Version 1.3
Issue 04/2006
47
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Adjusting Background adjustment method
Ι. Adjustment conditions
1) Adjustment item: Process mode: 
DLP menu 
GAMMA, 
R-GAIN, G-GAIN, B-GAIN
2) Input signal: Component video 75% white signal
1. With the component video 100% white signal, adjust the output to 0.7 
± 0.05 Vp-p
(excluding the synchronouspart.) (The sync signal is 0.3 Vp-p.)
2. Next drop the image signal output to 75%.
3. Input the signal to INPUT5 (DVI-I connector).
3) Target adjustment chromaticity
x = 0.290 
± 0.005
y = 0.311 
± 0.005 (Color temperature: 8500K, +6UV)
ΙΙ. Adjustment procedures
1) Select GAMMA from the DLP menu and set the value to “6”. (Initial value = 6)
2) Set R-GAIN, G-GAIN, B-GAIN to “96”. (Initial value = 95)
3) Background adjustment
1. Project on a 40-inch screen, and observe the chromaticity in the center with a
colour meter.
2. Fix G-GAIN to 95.
3. Adjust the x and y values to the target adjustment chromaticity with B-GAIN.
However, the adjusted value is up to 115 at maximum.
4. Adjust the x and y values to the target adjustment chromaticity with R-GAIN.
However, the adjusted value is up to 115 at maximum.
When the R-GAIN value is 115 and the x value cannot be adjusted,
1) Lower the B-GAIN and adjust to x = 0.290.
2) Lower the G-GAIN and adjust to y = 0.331.
5. Check that the middle gradation is not greatly deviated.
4) Exit the DLP menu by pressing the UNDO key on the remote control.
Page of 56
Display