XV-C2E (serv.man2). Service manual part one - Sharp Projector Service Manual (repair manual)

xv-c2e (serv.man2) service manual
Model
XV-C2E (serv.man2)
Pages
14
Size
539.77 KB
Type
PDF
Document
Service Manual
Brand
Device
Projector / Service manual part one
File
xv-c2e-sm2.pdf
Date

Read Sharp XV-C2E (serv.man2) Service Manual online

XV-C2E
1
SERVICE MANUAL
SERVICE-ANLEITUNG
PAL/SECAM/NTSC SYSTEM
LCD PROJECTOR
LCD PROJEKTOR
In the interests of user-safety (Required by safety regulations in some countries) the set should be restored
to its original condition and only parts identical to those specified should be used.
MODEL
MODELL
XV-C2E
Im Interesse der Benutzer-Sicherheit (in einigen Länder durch Sicherheitzvorschriften gefordert) sollte dieses
Gerät wieder auf seinen ursprünglichen Zustand eingestellt und nur die vorgeschriebenen Teile verwendet werden.
• SPECIFICATIONS .............................................. 2
• NOTE TO SERVICE PERSONNEL .................... 3
• OPERATION MANUAL ...................................... 4
• REMOVAL OF MAJOR COMPONENTS ............ 7
• OPTICAL SYSTEM .......................................... 11
• ADJ. IN FUNCTION ......................................... 13
• ELECTRICAL ADJUSTMENT .......................... 15
• TROUBLESHOOTING TABLE ......................... 21
• INTRODUCING THE NEW ICs ........................ 24
• CHASSIS LAYOUT .......................................... 45
• DESCRIPTION OF SCHEMATIC DIAGRAM ... 47
• WAVEFORMS .................................................. 48
• OVERALL WIRING DIAGRAM ......................... 49
• SCHEMATIC DIAGRAM ................................... 51
• PRINTED WIRING BOARD ASSEMBLIES ...... 70
• PARTS LIST
ELECTRICAL PARTS ................................. 77
CABINET AND MECHANICAL PARTS ....... 94
ACCESSORIES PARTS ............................ 101
PACKING PARTS ...................................... 101
• PACKING OF THE SET ................................. 102
• CEILING INSTALLATION ADAPTOR ............. 103
Page
CONTENTS
INHALT
Page
• TECHNISCHE DATEN ............................................
• HINWEISE FÜR DEN WARTUNGSTEHNIKER ......
• BEDIENUNG ANLEITUNG ......................................
• ENTFERNEN DER HAUPTTEILE ...........................
• OPTIKSYSTEM .......................................................
• FUNKTION ADJ IN ..................................................
• ELEKTRISCHE EINSTELLUNG ..............................
• TABELLE FÜR STÖRUNGSSUCHE .......................
• VORSTELLUNG DER NEUEN ICs .........................
• CHASSISANORDNUNGSPLAN .............................
• BESCHREIBUNG DES SCHEMATISCHEN
   SCHALTPLAN ......................................................
• WELLENFORMEN ..................................................
• GESAMTSCHALTPLAN ..........................................
• SCHEMATISCHER SCHALTPLAN .........................
• LEITERPLATTENEINHEITEN .................................
• TEILLISTE
ELEKTRISCHE TEILE .......................................
GEHÄUSE UND MECHANISCHE
   BAUTEILE .......................................................
ZUBEHÖR ..........................................................
VERPACKUNGSTEILE ......................................
• VERPACKEN DES GERÄTS ..................................
SHARP CORPORATION
XV-C2E
2
XV-C2E
3
NOTE TO SERVICE PERSONNEL
UV-RADIATION PRECAUTION
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
The light source,  metal halide lamp,  in the LCD
projector emits small amounts of UV-Radiation.
AVOID DIRECT EYE AND SKIN EXPOSURE.
To ensure safety please adhere to the following:
1. Be sure to wear sun-glasses when servicing the
projector with the lamp
turned “on” and the top
enclosure removed.
2. Do not operate the lamp outside of the lamp housing.
3. Do not operate for more than 2 hours with the
enclosure removed.
UV-Radiation and Medium Pressure
Lamp Precautions
1. Be sure to disconnect the AC plug when replacing
the lamp.
2. Allow one hour for the unit to cool down before
servicing.
3. Replace only with same type lamp.  Type
CLMPF0050DE02 rated     V/155W.
4. The lamp emits small amounts of UV-Radiation,
avoid direct-eye contact.
5. The medium pressure lamp involves a risk of
explosion.  Be sure to follow installation instructions
described below and handle the lamp with care.
DANGER !  –– Never turn the power on without
the lamp to avoid electric-shock or damage of the
devices since the stabilizer generates high voltages
at its start.
Lamp Replacement
Note:
Since the lamp reaches a very high temperature
during units operation replacement of the lamp should
be done at least one hour after the power has been
turned off.  (to allow the lamp to cool off.)
Installing the new lamp, make sure not to touch the
lamp (bulb) replace the lamp by holding its reflector
2
.
[Use original replacement only.]
1
2
Lamp
Reflector
XV-C2E
4
Location of Controls
Page of 14
Display

Download Sharp XV-C2E (serv.man2) Service Manual (Repair Manual)

Here you can read online and download Sharp XV-C2E (serv.man2) Service Manual in PDF. XV-C2E (serv.man2) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp XV-C2E (serv.man2) Projector. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.