XR-10X. Version 1.1 - Sharp Projector Handy Guide. Page 32

Read Sharp XR-10X Handy Guide online

Electrical Adjustments
Version 1.1
Issue 04/2006
32
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
1. Calling and quitting the process mode with the control keys on this model.
• 
Although it is possible for the process OUT to exit using the process menu, the IN/OUT
toggle command is also available considering the existing specification.
1-1. 
Calling and quitting
With the menu not displayed, press the "ENTER", "ENTER", "VOL+", "VOL-",
"ENTER", "ENTER" and "MENU" keys on the remote control (one for C50/45 or
P25/20 system is also usable) or on the main unit.
1-2. Others
Press the S2551 process key (toggle) on the main PWB to call and quit the process
menu.
Note:  When adjusting in the process mode, set a signal with a vertical frequency of 60 Hz
or no signal. (May not be properly adjusted with other signals.)
2. Resetting the lamp timer for this model
2-1. Resetting 
procedure
In Stand-by, run this command to clear the operating time of the lamp to 0 and turn
on the power.
Press and hold """, "ENTER", and "MENU", and then press the "STANDBY/ON" key
of the set.
3. Forced disabling of the System-Lock of this model
3-1. Disabling 
procedure
With System-Lock input window onscreen, press the "MENU", "ENTER", "ENTER",
"MENU", "ENTER", "ENTER" and "MENU" keys, in this order, on the remote
controller.
Page of 42
Display