XG-XV2E (serv.man3). Service manual part two - Sharp Projector Service Manual (repair manual). Page 10

Read Sharp XG-XV2E (serv.man3) Service Manual online

XG-XV2E/M/A
146
7
6
5
4
3
2
1
A
B
C
D
E
F
G
H
DESCRIPTION OF
SCHEMATIC DIAGRAM
VOLTAGE MEASUREMENT CONDITION:
1. Voltages at test points are measured at the
supply voltage of AC 120V.  Signals are fed by a
color bar signal generator for servicing purpose and
the above voltages are measured with a 20k ohm/V
tester.
WAVEFORM MEASUREMENT CONDI-
TION:
1. Waveforms at test points are observed at the supply
voltage of AC 120V.  Signals are fed by a color bar
signal generator for servicing purpose.
INDICATION OF RESISTOR & CAPACI-
TOR:
RESISTOR
1. The unit of resistance “
” is omitted.
(K=k
=1000 
,  M=M
).
2. All resistors are 
±
 5%,  unless otherwise noted.
(J= 
±
 5%, F= 
±
 1%, D= 
±
 0.5%)
3. All resistors are 1/10W,  unless otherwise noted.
4. All resistors are Carbon type,  unless otherwise
noted.
 
C
 : Solid
W
 : Cement
 
S
 : Oxide Film
 
T
 : Special
 
N
 : Metal Coating
CAPACITOR
1. All capacitors are 
µ
F,  unless otherwise noted.
(P=pF=
µµ
F).
2. All capacitors are 50V,  unless otherwise noted.
3. All capacitors are Ceramic type,  unless otherwise
noted.
(ML): Mylar
(TA): Tantalum
(PF): Polypro Film
(ST): Styrol
CAUTION:
This circuit diagram is original one,  therefore there may be a
slight difference from yours.
SAFETY NOTES:
1. DISCONNECT THE AC PLUG FROM THE AC
OUTLET BEFORE REPLACEING PARTS.
2. SEMICONDUCTOR HEAT SINKS SHOULD BE
REGARDED AS POTENTIAL SHOCK HAZARDS
WHEN THE CHASSIS IS OPERATING.
IMPORTANT SAFETY NOTICE:
PARTS MARKED WITH  “ 
å 
(
) ARE
IMPORTANT FOR MAINTAINING THE SAFETY OF
THE SET.  BE SURE TO REPLACE THESE PARTS
WITH SPECIFIED ONES FOR MAINTAINING THE
SAFETY AND PERFORMANCE OF THE SET.
Page of 13
Display