XG-XV2E (serv.man2). Service manual part one - Sharp Projector Service Manual (repair manual). Page 20

Read Sharp XG-XV2E (serv.man2) Service Manual online

20
XG-XV2E/M/A
Replacing the LCDs
With the top cabinet removed
(1) Remove three screws off the output shield.
(2) Disconnect the LCD flat cable from the output PWB connector.
(3) Remove the lock screws "b" and "c". Detach the R/B adjusting plate or the G adjusting plate together with the
LCD panel.
(4) Separate the LCD panel from the adjusting plate.
(5) Mount a new LCD panel in the reverse order of the above steps (1), (2), (3) and (4).
~
Readjust the convergence and focus. Note that the G LCD panel needs no convergence adjustment and has
a small adjustment range in the Z direction.
X
Z
θ
Y
TOP VIEW
X
Z
θ
Y
Lock screws "c"
Lock screws "c"
Lock 
screws "c"
Lock 
screws "b"
FRONT
R-LCD
B-LCD
G-LCD
2
2
3
3
3
3
1
1
2
SIDE VIEW
SIDE VIEW
X
Y
θ
Z
R•B adjusting plate
R•B-LCD
R•B-LCD panel
mounting screws
4
G-LCD panel
mounting screws
4
 G adjusting plate
G-LCD
1
Page of 47
Display

Click on the first or last page to see other XG-XV2E (serv.man2) service manuals if exist.