XG-XV2E (serv.man2). Service manual part one - Sharp Projector Service Manual (repair manual). Page 12

Read Sharp XG-XV2E (serv.man2) Service Manual online

12
XG-XV2E/M/A
4. Removing the left side cabinet
4-1. Put a bladed screwdriver in the rightmost hole of the screws cover. Pull and unlock the right end of the
screws cover, and pull and detach the entire screws cover.
4-2. Remove the twelve side screws.
4-3. Remove the two screws off the side cabinet.
4-4. Disconnect the video terminal cover.
4-5. Disconnect the membrane switch connector.
4-6. Pull down and detach the left side cabinet.
4-7. Remove the two screws off the LED PWB assembly.
4-2
4-4
4-2
4-2
4-6
4-3
4-5
4-3
4-7
LED Unit
Left-Side
Cabinet
Video Terminal Cover
(attached only when the video
board unit is not used)
4-4
4-2
4-2
4-1
Video Board Unit
(for XG-XV2M as 
well as Australian 
and NewZealand 
versions of 
XG-XV2E)
Video Terminal Cover
(for XG-XV2M as well as 
Australian and NewZealand 
versions of XG-XV2E)
Page of 47
Display

Click on the first or last page to see other XG-XV2E (serv.man2) service manuals if exist.