XG-V10WE (serv.man26). Projector does not turn on (Power LED Flashes Red) - Sharp Projector Technical Bulletin (repair manual). Page 3

Read Sharp XG-V10WE (serv.man26) Technical Bulletin online

RG002
Sharp Electronics (UK) Ltd., Technical Services Group
8. Turn off the power of V10WE.
After the Firmware upgrade has been completed
1-1.Turn on the power of V10WE (with the lamp on).
Note
You will find that after the firmware upgrade all inputs display a white screen.
This is not the upgrade failure. Complete the following.
1-2. Enter factory adjust mode.
The following key sequence accesses the service menu:
mute / mute / vol up / vol down / enter / enter / menu
1-3. Record the following adjustment value of the product.
Group
Subject
A/D
all
DTV
all
OUTPUT3 SH-PHASE, 
GCK-PHASE
VIDEO2
R1-BLK, R1-GAIN, B1-BLK, B1-GAIN   
2-1. Select the following group and subjects.
group   : SSS
subject : S1
2-2.With the cursor position on S1, press the ENTER key on V10WE's operation key.
3. Lens shift initialise
3-1.Ensure you are in the factory adjust mode.
3-2.Select the following group and subject.
group   : LENS
subject : LENS AUTO
3-3.With the cursor position on LENZ AUTO, press the ENTER key on V10WE's operation key.
3-4.Automatically lens shift moves up and down, then that's finished.
4.Electrical adjustment
4-1. Input the numerical value recorded with a process 1-3.
4-2. Change the numerical value of the following item.
Group
subject
new value
A/D
R-D
inputted value + 6
A/D
G-D
inputted value + 38
A/D
B-D
inputted value + 3
VIDEO2
R1-BLK
inputted value - 3
VIDEO2
R1-GAIN
inputted value + 1
VIDEO2
B1-BLK
inputted value - 5
VIDEO2
B1-GAIN
inputted value + 3
5-1. Select the following group and subjects.
group    : SPECIAL
subject  : E2PROM
5-2. Change the numerical value of ADR-H to 128.
5-3. Change the numerical value of ADR-L to 118.
Page of 4