Read Sharp XG-SV1E (serv.man6) Technical Bulletin online
LV-059
Sharp Electronics (UK) Ltd., Technical Services Group
6-3. Replace the existing poralizer input filter-G (at the position of #3) with new type(*).
6-4. Replace the existing poralizer input filter-B (at the position of #5) with new type(*).
6-5. If your model is either XG-E3500U, XG-XV2E, XG-XV2M or XG-XV20A, add the DR glass-B
(PFILWA015WJZZ) at the position of #6.
6-6. Remove a screw #7.
If your model is either XG-E3000U, XG-XV1E, XG-XV1A, XG-E3500U, XG-XV2E, XG-XV2M or
XG-XV20, remove the existing aperture # 8-87. (Refer to the service manual.)
6-7. Fix the UV absorption filter(PFILWA016WJZZ) with angle LANGGA002WJFW) at the position of #7
by tightening the screw.
6-4. Replace the existing poralizer input filter-B (at the position of #5) with new type(*).
6-5. If your model is either XG-E3500U, XG-XV2E, XG-XV2M or XG-XV20A, add the DR glass-B
(PFILWA015WJZZ) at the position of #6.
6-6. Remove a screw #7.
If your model is either XG-E3000U, XG-XV1E, XG-XV1A, XG-E3500U, XG-XV2E, XG-XV2M or
XG-XV20, remove the existing aperture # 8-87. (Refer to the service manual.)
6-7. Fix the UV absorption filter(PFILWA016WJZZ) with angle LANGGA002WJFW) at the position of #7
by tightening the screw.
•
For parts code, refer to the parts table of the “Details of parts kit” in the page 2.