[12] Removing the Filter Unit
1. Disconnect all the connectors from the filter unit. Remove the four screws from the filter unit and then take it out.
[13] Removing the IR (Back) Unit
1. Disconnect all the connectors from the power channel. Remove the six screws from the Handle Bracket 2 and then take out the Handle Bracket 2.
2. Remove the screw from the IR (Back) unit and detach the IR (Back) unit.
3. Remove the four screws from the Direct off unit and then take it out.
12-1
Filter Unit
Chassis
PR1
PR2
PR3
PR1
PR2
PR3
IR (Back) Unit
14-1
Power Channel
Handle Bracket 2
Chassis
14-2
Direct Off Unit
Insulator
14-1
14-1