XG-PH70X (serv.man10) - Sharp Projector User Guide / Operation Manual. Page 10

Read Sharp XG-PH70X (serv.man10) User Guide / Operation Manual online

XG-PH70X/XG-PH70X-N
1 – 10
[4] Maintenance Indicators
Power indicator
Lamp indicators 1, 2
Temperature warning indicator
Maintenance Indicators
Maintenance Indicators
The warning lights on the projector indicate problems inside the projector.
If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate
red, and the projector will enter the standby mode. After the projector has entered the standby
mode, follow the procedures given below.
About the temperature warning indicator
If the temperature inside the projector increases, due to blockage of the air vents, or the setting location,
"
" will illuminate in the lower left corner of the picture. If the temperature keeps on rising, the lamp will
turn off and the temperature warning indicator will blink, the cooling fan will run for a further 90 seconds, and
then the projector will enter the standby mode. After "
" appears, ensure you perform the measures
About the lamp indicator
"Change The Lamp. (LAMP 2)" is displayed when the remain-
ing life of the lamp 2 becomes 5% or less.
ı
When the remaining lamp life becomes 5% or less,"
" (yellow) and "Change The Lamp. (LAMP 1/2)"
will be displayed on the screen.
ı
When the percentage becomes 0%, it will change to "
"(red), the lamp will automatically turn off. At
this time, the lamp indicator will illuminate in red.
If you try to turn on the projector a fourth time without replacing the lamp, the lamp whose life is 0%
will not light up.
Page of 15
Display

Click on the first or last page to see other XG-PH70X (serv.man10) service manuals if exist.